Specification
MIN1/2"
MAX 1.2"(30MM)
Push flange on pot filler,mark
locating hole on wall
21
5
With 1.8 gpm are compliant with
California water effi ciency regulations,
Complies with California Proposition
65 and with the Federal Safe Drinking Water Act.
In areas with extremely low water pressure causing
the faucet water flow to be unsatisfactory ,
replace the aerator to improve the water flow in the faucet.
WARNING: Connect to
Cold Water Only.
Wrap plumber tape around pipe
threads
Connect to 1/2" IPS supply line.
Ø15/64"
(Ø6MM)
Drill holes and insert plugs
3
Wrap plumber tape (1) around pipe
threads.
Install the gasket (2) and the flange
(3) using the 4 screws provided.
4
Teflon tape
1
2
Place flange trim (1) onto the faucet .
Thread faucet ontopipe.
Tighten securely, but do not overtighten.
Screw on pot filler
Screw in screw by using an 1.5mm
allen wrench to fasten pot filler to
flange .
6
Remove aerator (1) and turn faucet handles (2)
to the full on position.
Turn on cold water supplies and flush water lines
for one minute.
Important: This flushes away any debris that
could cause damage
to internal parts.
Check all connections at arrow for leaks.
Re-tighten if necessary, but do
not overtighten.
If faucet leaks out of spout or handle - Replace valve cartridge (4).
Remove handle(1), ring(3)and screw (2). Unscrew and replace valve
cartridge, 1.5 mm hex. Assemble in reverse order. Line up handles with
valves in closed position before pushing handles into place.
1
2
3
4
1
2
3
4