Technical data
12
• Reinstall fine adjustment guide (F) onto guide rods rotate 180
degrees from normal position so that circle guide hole faces away
from the router.
• Insert the guide rods (C) into router base. For maximum
stability, make sure each rod goes through both holes and protrudes
out the other side of the router base (At a maximum, the rods must
be inserted far enough into the router base that they are supported
from below base.
• Securely fasten the router to the rods by tightening the locking
screws (12). The largest circles and arcs can be made when the
guide rods enter the side of the router where the locking screws (12)
are located.
• Mark the workpiece at the center of the desired circle.
• Using the centering slots on the edge of the pivot plate (22), center
the pivot plate on the center mark and attach to the workpiece with
several strips of strong tape placed over the pivot plate in a crisscross
pattern.
• Place fine adjustment guide (F) on pivot plate (22) so the hole in
fine adjustment guide (F) fits over the steel pin.
• Adjust the position of the rods and router as necessary to achieve
the desired radius of the circle or arc, then securely tighten wing
knobs.
CARBON BRUSH REPLACEMENT (ONLY FOR WU600 AND
WU600.1)
Always be sure that the tool is switched off and unplugged before
attempting to perform inspection or maintenance.
There are 2 motor brushes which can be easily accessed on either
the front or back of the motor housing.
Attention: When servicing a tool, ALWAYS use only identical
replacement parts.
STEP 1: Locate the plastic motor brush caps on both the front and
back of the motor housing.
STEP 2: Remove the threaded access cap on accessible carbon
brushes (30) with a flathead screwdriver and turn the screw in a
counter-clockwise rotation to loosen.
STEP 3: Gently remove the old motor brush.
STEP 4: Carefully insert the replacement brush. Ensure the brush is
completely inserted into the holder and is seated properly and is free
to move inside its holder.
STEP 5: Replace the access cap with the flat-head screwdriver,
turning clockwise to tighten. Do not apply excessive force as this may
damage the access plug.
Note: Always change both sets of brushes at the same time.
13