SDS

_____________________________________________________________________________________________
1363551 - Positec WA3578 20v 4.0Ah battery
Revision Date 17-Jan-2017
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
The following ingredients are the only ingredients of the product above the cut-off level (or
level that contributes to the hazard classification of the mixture) which have an exposure
limit applicable in the region for which this safety data sheet is intended or other
recommended limit. At this time, the other relevant constituents have no known exposure
limits from the sources listed here
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1 mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu dust,
fume, mist
IDLH: 100 mg/m
3
dust, fume and mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Glass fiber
65997-17-3
TWA: 1 fiber/cm3 respirable fibers:
length >5 µm, aspect ratio >=3:1, as
determined by the membrane filter
method at 400-450X magnification
[4-mm objective], using phase-contrast
illumination
TWA: 5 mg/m
3
inhalable particulate
matter
-
Lithium nickel oxide
(LiNiO2)
12031-65-1
TWA: 0.2 mg/m
3
Ni inhalable
particulate matter
TWA: 1 mg/m
3
Ni
(vacated) TWA: 1 mg/m
3
Ni
IDLH: 10 mg/m
3
Ni
TWA: 0.015 mg/m
3
except Nickel
carbonyl Ni
Aluminum
7429-90-5
TWA: 1 mg/m
3
respirable particulate
matter
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total dust
(vacated) TWA: 5 mg/m
3
respirable
fraction (vacated) TWA: 5 mg/m
3
Al
Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Lithium manganese oxide
(LiMn2O4)
12057-17-9
TWA: 0.2 mg/m
3
Mn (vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
Manganese
7439-96-5
TWA: 0.02 mg/m
3
respirable
particulate matter
TWA: 0.1 mg/m
3
inhalable particulate
matter TWA: 0.02 mg/m
3
Mn respirable
particulate matter
TWA: 0.1 mg/m
3
Mn inhalable
particulate matter
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 3 mg/m
3
fume
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
fume Ceiling: 5
mg/m
3
Mn
IDLH: 500 mg/m
3
TWA: 1 mg/m
3
fume
STEL: 3 mg/m
3
Lithium Cobalt Oxide
(CoLiO2)
12190-79-3
TWA: 0.02 mg/m
3
-
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this
product. Take off contaminated clothing and wash before reuse.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up.
Keep out of the reach of children.
Incompatible Products
Strong acids. Strong oxidizing agents. Strong bases.
_____________________________________________________________________________________________
Page 5 / 14