User's Manual

16
2 of 5 Data Length
2 of 5 Code is so susceptible to interpreting partial scans as valid reads
that the Radio/Freedom Reader uses fixed-length data as a safeguard. To
choose a data length, scan it as a two-digit number using the Barpad Table.
For example, to select 8-digit data length, you would scan a 0 and then an 8.
Because Interleaved 2 of 5 is required to be an even number of digits in
length, you must use an even number. If you're unsure of your bar code
length, temporarily set the length to 00, read a bar code, and count its digits
and then set it to the actual length. DO NOT PERMANENTLY SET THE 2
of 5 LENGTH TO 00 or you will get misreads!
Code 93
Enable Code 93 0
Disable Code 93
1
Enable Full ASCII Code 93 2
Disable Full ASCII Code 93 3
For more information on Code 93 see Appendix D.
Terminator characters
Enter (carriage return) 0
None 1
HT 2
CR/LF 3
Depending on your application, you may wish your Wireless Reader to
transmit bar code data to your computer with an Enter (carriage return), a Tab
at the end, or with no extra terminating character at all.
If you need a terminator character other than CR or HT or CR/LF, you can
get it by specifying None here and then selecting your desired terminator
character(s) specified in the Postamble (See Page 18).
Preamble
A "Preamble" is a user-specified data string transmitted at the beginning of
each bar code. For example, if you specify the preamble @@ and read data of
123456, "@@123456" would be transmitted to your computer. With the 2-
Way LZ2x2-RF Laser, the Preamble applies to the scanner, not the base
station because there may be multiple scanners per base.
The default is no preamble. To select a preamble, scan up to 15 characters from
the "FULL ASCII MENU" on the back of the Reader Setup Menu, and then scan
SET when you're done. To return to the no preamble setting, scan Clear here
instead of scanning SET or any characters from the FULL ASCII MENU.