User's Manual

Table Of Contents
6-15
ComDeviceName
Valid values: COM1-COM16
Definition: This is the serial port that this instance of the control will
use. If you have more than one base station, drop in
another WDterm control and set its ComDeviceName for
your other COM port(s).
ComBaudValue
Valid values: 300, 600, 1200, 2400, 4800, 9600, 19200
Definition: This is the serial port speed setting and must match the
base station setting.
ComParity
Valid values: None, Even, Odd.
Definition: This is a serial port setting and must match the base station
setting. WDterm may allow other settings but those listed
here are the only ones compatible with current version base
stations.
ComDataBits
Valid values: 7, 8
Definition: This is a serial port setting and must match the base station
setting. WDterm may allow other settings but those listed
here are the only ones compatible with current version base
stations.
ComStopBits
Valid values: 1, 2
Definition: This is a serial port setting and must match the base station
setting. WDterm may allow other settings but those listed
here are the only ones compatible with current version base
stations.
FlowControl
Valid values: None, XON/XOFF
Definition: This is a serial port setting and must match the base station
setting.
Quiet
Valid values: True, False
Definition: If Quiet is set to True then any status and error message
generated by WDterm will be suppressed.