Service manual

– 26 –
GENERAL ADJUSTMENTSSPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
Data
HIGH VOLTAGE AT ZERO BEAM: (A) 31.0 kV
MAX HIGH VOLTAGE:
(B) 31.3 kV
Table-1
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
X-RAY RADIATION PRECAUTION
CHAPTER 2 SPECIFIC INFORMATIONS
Table-2
RCUT
GCUT
BCUT
RDRV
BDRV
CNTX
BRTC
COLC
TNTC
SCOL
SCNT
HPSD
R CUTOFF
G CUTOFF
B CUTOFF
R DRIVE
B DRIVE
SUB-CONTRAST MAX
SUB-BRIGHT CENTER
SUB-COLOR CENTER NTSC
SUB-TINT CENTER
SUB-COLOR
SUB-CONTRAST
H-POS (FULL)
Item Name of adjustment
Data
40H
40H
40H
40H
40H
7FH
80H
50H
46H
06H
0CH
85H
Item Name of adjustment
Data
HIT
VLIN
VSC
VCP
WID
TRAP
HCP
VFC
PARA
VCEN
VPOS
V-HEIGHT (FULL)
V-LINEARITY (FULL)
V-S CORRECTION (FULL)
V-COMPENSATION (FULL)
PICTURE WIDTH (FULL)
TRAPEZIUM (FULL)
H-COMPENSATION (FULL)
V-F CORRECTION (FULL)
PARA (FULL)
V-CENTER (FULL)
V-POSITION (FULL)
41H
0FH
08H
07H
17H
09H
00H
00H
10H
83H
00H
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Data
Item Name of adjustment
Preset Data 65" 56"
Remarks
Table-3
CIRCUIT CHECKS
FBT DETECTION VOLTAGE (C) 39.0 V
Table-4
OPT0 OPTION 0 00H 02H 02H
OPT1 OPTION 1 01H 01H 01H