Service manual

– 15 –
GENERAL ADJUSTMENTSSPECIFIC INFORMATIONS
ITEMS NAMES SETTING
INPUT MEASURING MEASURING
ADJUSTING METHODS
ADJUSTMENT
SIGNALS POINTS INSTRUMENTS
STANDARS
High voltage
adjustment
(Unit)
fH. ADJ.
(Chassis)
HPOS
(Chassis)
CONTRAST :MAX
BRIGHTNESS :CNT
COLOUR :CNT
TINT :CNT
CNTRAST :MAX
BRIGHTNESS :CNT
COLOUR :CNT
TINT :CNT
CONTRAST :MAX
BRIGHTNESS :CNT
COLOUR :CNT
TINT :CNT
Retoma signal
Retoma signal
Retoma signal
Between
T461-Z450
Between
R431-GND
D441-K
(2V/div range)
R4011-BB50 side
(1V/div range)
High voltage
meter
Frequency counter
Synchroscope
1) Perform connection of the high
voltage meter between T461-Z450
and adjust high pressure with R466.
1) Short-circuit test pin (H) and (+9V).
2) Adjust fH with R4055.
1) Adjust DC=0 of both wave forms to
the lowest line on the synchroscope.
2) Take measurement of 3 div.
3) Observe the wave forms at the two
points and make adjustments with the
HPOS.
Horizontal
oscillation
frequency
Horizontal
phase
31.0±0.2kV
33.75±
0.15kHz
A=0.76±0.1[µs]
D441 cathode wave form
3div
BB connector side wave
form of R4011
0
A
ELECTRICAL ADJUSTMENT