GENERAL ADJUSTMENTSSPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
40~61"
HIGH VOLTAGE AT ZERO BEAM: (A) 31.5 kV
MAX HIGH VOLTAGE:
(B) 32.6 kV
Table-1
CHAPTER 2 SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATA IN THE SERVICE MODE:
Item Name of adjustment
R CUTOFF
G CUTOFF
B CUTOFF
R DRIVE
B DRIVE
SUB CONT MAX
SUB-BRIGHT
SUB-COLOR
SUB-TINT
SUB COLOR
SUB-CONTRAST
HORIZ. POSITION
VERT. POSITION
HEIGHT
V-LINEARITY
V-S CORRECTION
PICTURE WIDTH
RCUT
GCUT
BCUT
RDRV
BDRV
CNTX
BRTC
COLC
TNTC
SCOL
SCNT
HPOS
VPOS
HIT
LIN
VSC
WID
Preset Date
40H
40H
40H
40H
40H
7FH
80H
50H
44H
05H
10H
6DH
00H
64H
12H
10H
23H
55H
Table-2
CIRCUIT CHECKS
Table-3
FBT DETECTION VOLTAGE (C) 24.5V
Item Name of adjustment Preset Date
VPS
PYOF
PIOF
PQOF
VCP
PARA
CNR
TRAP
HCP
VFC
PHUE
PCNT
PCOL
VCEN
TVOP
OPT0
OPT1
V-SHIFT
PIP Y OFFSET
PIP I OFFSET
PIP Q OFFSET
V-COMPENSATE
E-W PARABOLA (DPC)
E-W CORNER
TRAPEZIUM
H-COMPENSATE
V-F CORRECT
PIP TINT
PIP CONT
PIP COLOR
V POSITION
TV OPTION
TV SET OPTION
TV SET OPTION
0AH
17H
24H
1EH
0AH
29H
08H
0CH
00H
00H
40H
10H
15H
70H
00H
50H
05H