User manual

Read Mode Settings Continued:
Add-on
Delay Timer
disable add-on wait more default
YB
add-on wait mode = 0.25 seconds
YC
add-on wait mode = 0.50 seconds
YD
add-on wait mode = 0.75 seconds
YE
Since WPC-type codes (UPC, EAN) with add-on (supplements) have a high probability of
unsuccessful decoding, the scanner repeats decoding the add-on code during the specified period of
time. It is effective to read the add-on parts, but it will also cause a reduced response when a code
without an add-on is read.
Margin Check
(Quiet Zone)
no margin check
/ZO
margin check 1/7 normal
ZP
margin check 2/7 normal
ZQ
margin check 3/7 normal
ZR
margin check 4/7 normal
ZS
margin check 5/7 normal
ZT
margin check 6/7 normal
ZU
margin check normal default
ZV
Power Saving
disable power saving (USB I/F default) default
YTD
power saving after 0 seconds (RS-232 I/F default) default
F75
power saving after 1 second
YTI
power saving after 2 seconds
FC1
power saving after 5 seconds
FC2
power saving after 10 seconds
FC3
power saving after 30 seconds
YTE
power saving after 10 minutes
YTF
power saving after 30 minutes
YTG
power saving after 60 minutes
YTH
A-48