Owner`s manual

where b is the Bar Code ID character (see the Code 128 setup parameter) and x is the number of
characters to trim from the end of the data. For example, ~b2~c1 says “trim 2 characters from Code 39
data and 1 character from UPC-A data”. Remember that the Postamble trims trailing data.
Lastly, the Postamble can be used to check a maximum character length for data entered. To check for
length in the Postamble, enter:
|nnmm
where | is ASCII 124, nn is the two-digit minimum and mm is the two-digit maximum. |0210 would
check for a minimum of 2 characters and a maximum of 10 If you try to scan a bar code outside the
minimum or maximum lengths, no decode will result. Entering data by keypad is not affected.
Characters
This setting allows the RF Terminal to output chosen ASCII characters in place of the actual characters
entered. For example, if you scanned the number 1 (hex 31) and wanted the RF Terminal to output hex 92
instead, you would enter 3192 for the Characters parameter. This would re-assign the output characters,
with the RF Terminal outputting hex 92 every time it sees hex 31. To re-assign characters:
Select option “8” from the RF Terminal Setup menu then “3” to enable character entry. A square cursor
will appear.
Enter up to seven 4-digit pairings where the first 2 digits represent the hex number to replace and the second 2
digits represent the hex number to insert. You can have up to seven character reassignments.
Press “Enter” when done or “Clear” to reset to none.
You can eliminate the output of a character by using FF as the hex number to insert. For example, if you
wanted to eliminate all $, following the above instructions, enter 24FF.
System Tools
Download File
This will allow you to update the terminal's voice prompts when using the 7802 RF Terminal Voice Prompts
Manager program.
Play Voice Prompt
To play a voice prompt, select option “2” then enter the 2-digit number of the voice prompt that you wish to
play. The valid range is 01 to 99.
Reset to Factory Default
Select option “3” to reset all setup values to the factory default values. This will reset all values in all menus
of the RF TERMINAL SETUP.
Host Interface
Select option 4 to toggle between USB and Serial interface. This only applies to the host interface for
firmware updates and voice prompt file downloads. The default is USB.
33