HOMEOWNER’S INSTALLATION AND OPERATING INSTRUCTIONS COMFORT GLOW ELECTRIC LOG SET INSERT/ ELECTRIC LOG SET INSERT WITH FIREBACK MODEL #ELCG 240 / ELCG 347 IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! C US IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLER: Leave this manual with the appliance.
TABLE OF CONTENTS Safety Information............................................................................................................................. 3 Installation Instructions...................................................................................................................... 6 Operation Instructions....................................................................................................................... 9 Care and Maintenance......................................
SAFETY INFORMATION SAVE THESE INSTRUCTIONS Please read and understand this entire manual before attempting to assemble, operate or install the product. If you have any questions regarding the product, please call customer service at (814) 643-1775, 8:30 am to 5:00 pm EST, Monday – Friday. 1. Read all instructions before using this appliance. 2. This appliance is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this appliance.
SAFETY INFORMATION DANGER Electrical Connection A 15-Amp, 120-Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the log set will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with a 6 ft. (1.8 m) long three wire cord, exiting the right side of the log set. Plan the installation to avoid the use of an extension cord.
SAFETY INFORMATION Remote Control This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Industry Canada ICES-003. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
INSTALLATION INSTRUCTIONS Log Set Dimensions C D D B B C Α Α Model #ELCG 240 Ref.
INSTALLATION INSTRUCTIONS Package Contents A B GHP PART DESCRIPTION QUANTITY A Electric Log Set with Heater 1 B Infrared Remote Control 1 7
INSTALLATION INSTRUCTIONS Your new electric log set with heater can be installed in several ways: • Into an existing fireplace. • On a solid floor up against a solid wall. • Into any opening or enclosure that meets the clearances to combustibles listed below. Simply place your electric log set in the desired location, observing the clearances and notes in this manual, and plug the cord into a minimum 15 amp, 120 Volt electrical outlet. Use an extension cord rated for a minimum of 1,875 watts if necessary.
OPERATING INSTRUCTION The log set control functions can be accessed in two (2) ways: • Using the control panel buttons, located on the lower right-hand corner of the log set. • Using the multifunction remote control unit. The log set conveniently features separate controls for flame effect and for heater control. This allows you to operate the unit in two (2) different modes: • As a full-featured log set - both flame effect and heater are on.
OPERATING INSTRUCTION The infrared remote control relies on a line of sight and must be pointed at the controls of the log set to work. The remote control unit has the controls required to turn ON/OFF both the main power and the heater. If you prefer to use the control buttons on the log set unit itself, they are on the lower right corner of the unit. The layout of the buttons and remote control unit can be seen in Figures 3 and 5, respectively. 1. Plug your log set into a 15-amp, 120-volt power outlet. 2.
CARE AND MAINTENANCE Before attempting ANY maintenance: 1. Turn off power to the unit. 2. Unplug the power cord from outlet. 3. Let log set cool if it has been operating. Maintenance of Motors: Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation. The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and require no further lubrication.
ELECTRIC WIRING DIAGRAM Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes. CIRCUIT DIAGRAM DANGER Disconnect power before servicing. Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1 Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/NFPA NO 70.
TROUBLESHOOTING If you have any questions regarding the product, please call customer service at (814) 643-1775 8:30 a.m. – 5:00 p.m. EST, Monday – Friday. Problem Possible Cause Corrective Action Log set does not operate; the ON/OFF power light on the control panel is not lit. 1. The log set is not plugged in. 1. Make sure the log set is plugged in to a standard 120V outlet. 2. A circuit breaker is tripped or a fuse blown. 2.
WARRANTY The manufacturer warrants that your new electric log set is free from manufacturing and material defects for a period of one year from date of purchase, subject to the following conditions and limitations. 1. This electric log set must be installed and operated at all times in accordance with the instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty. 2.
REPLACEMENT PARTS LIST For replacement parts, call our customer service department at (814) 643-1775, 8:30 a.m.- 5:00 p.m. EST, Monday – Friday. Ref.
Printed in China 16