Installation manual
Page 18
OPTIONAL ACCESSORIES: Purchase these heater accessories from your local
distributors/dealers. If they can not furnish these items, call World Marketing of America, Inc.
@1-814-643-2299 for more detailed information.
FLOOR MOUNTING BASE : N
O. 20-5231 may be used for MODEL(KWN 305, KWP 306).
No. 20-5221 may be used for MODEL(KWN 205, KWP 206).
"DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET"
NOTE
: For altitudes above 2,000 feet, reduce the input rating(BTU/HR)4% for
each 1,000 feet above sea level.
SPECIFICATIONS:
MODELS
KW(N305,P306)
N305 P306
KW(N205,P206)
N205 P206
INPUT RATING
(BTU/HR,Variable) 30,000/17,400
NATURAL LP GASES NATURAL LP GASES
30,000/17,400 20,000/11,700 20,000/11,700
TYPE OF GAS
REGULATOR
PRESSURE
SETTING
INLET GAS SUPPLY
PRESSURE:
MAXIMUM
MINIMUM
3.0″W.C.
10.5″W.C.
4.0″W.C.
8.0″W.C.
14.0″W.C.
11.0″W.C.
3.0″W.C.
10.5″W.C.
4.0″W.C.
23.8″×25.7″×8″
30LBS
23.8″×18.3″×8″
22LBS
8.0″W.C.
14.0″W.C.
11.0″W.C.
SIZE OF HEATER
(H×W×D)
WEIGHT