User guide
19
AFTER SALES SUPPORT
t
0151 649 1500 www.einhell.co.uk
D
1890 946 244
WZK 182
05/2013
Possible causes of failure
Problem Cause Solution
The compressor
does not start
1. No supply voltage
2. Insufficient supply
voltage
3. Outside temperature
is too low
4. Motor is overheated
1. Check the cable, power
plug, fuse and socket-
outlet.
2. Make sure that the
extension cable is not too
long. Use an extension
cable with large enough
wires cross-sections.
3. Do not use at an outside
temperature below +5° C.
4. Allow the motor to
cool down. If necessary,
remedy the cause of the
overheating.
The compressor
starts but there
is no pressure
1. The non-return valve
has a leak.
2. The seals are
damaged.
1. Replace the non-return
valve.
2. Check the seals and
have any damaged seals
replaced by a service
center.
The compressor
starts, but the
tools do not.
1. Loose hose
connections.
2. Leak in a quick-lock
coupling.
1. Check the compressed air
hose and tools and replace
if necessary.
2. Check the quick-lock
coupling and replace if
necessary.
Spare parts list
WZK 182 • Art.-No.: 40.205.49 • ID-No.: 11012
Item Description Spare part number
06 Tyre pressure gauge (incl. hose and
blow-out adapter)
402054501001
8-piece adapter set 402054501002
WZK_182_UK_SPK7.indb 19 22.11.12 14:00