Troubleshooting Tips
The Lincoln Under-cabinet Light will not turn on
Check all wire and cable connections. Make sure they are
completely and fully engaged.
Check that the jumper cables or power adapter cables have
not come loose from their connectors
Make sure that the Transformer is plugged into the wall.
If a daisy chain, ensure the correct transformer is used for
the number of LEDs in the chain. All transformers should
be Class 2, 12V transformers. Refer to the Table in Step 2
for required current ratings.
Check that the outlet has power.
The Lincoln Under-cabinet Light ashes on and off
Unplug the transformer and locate the label. Make sure
that the transformer is ONLY a Class 2, 12V transformer
at 1A (1000mA), 2A (2000mA), or 4A depending on how
many LEDs are connected.
The Lincoln Under-cabinet Light dims or goes out.
Make sure there are not too many lights in the daisy chain
for the rating of the transformer. Refer to the Table in Step
2 for guidance.
Check all wire and cable connections. Make sure they are
completely and fully engaged.
Check that the outlet has power.
The Lincoln Under-cabinet Light will not turn on when I
come back into the work area
The occupancy sensor has a listed range of 15’. However,
if a lip of the cabinet or other object blocks the full view
of the sensor, then it may have trouble detecting the
presence of a person in the work area. Reposition the light
to have a better view of the work space.