Technical data

70
CTC EcoZenith i550 Pro
For the property owner
9.5.3.8 Def cooling
If cooling has been defined there is no heating circuit 3.
Cooling No (No/Yes)
This is for selecting whether cooling has been installed.
Condense pipe secured Yes (Yes)
If a condense pipe for the system has been secured,
significantly lower temperatures are permitted at
various points in the system. WARNING Build-up of
condensation in the house structure can lead to damp
and damage from mildew. In the event of doubt, contact
an expert surveyor for an assessment.
Room temp. cooling 25 (10...30)
This is where the desired room temperature for cooling
is set.
See CTC EcoComfort manual for more
information.
!
A room sensor must always be used
in that part of the property which
is to be cooled, as it is the room
sensor which determines/controls
cooling capacity.
9.5.3.9 Define wood boiler
Wood boiler (03) No (No/Yes)
This is for selecting whether a wood boiler is installed in
the system.
9.5.3.10 Define external boiler
Ext boiler (04) No (No/Yes)
Selected if an external boiler (04) has been connected to
the system.
Sensor ext boiler No (No/Yes)
Selected if a sensor in an external boiler has been
connected to the system.
Def. Pool
Pool (G50, G51, B50) No (No/yes)
Selected if a pool with circulation pumps (G50) and (G51)
and sensors (B50) has been connected to the system.
Def. Solar Panels
Solar Panels (G30, B30, B31) No
Type Coil
Vacuum No
Bore hole recharge (Y31, G31) No
Define El.heaters
Upper el.heater Yes
Upper opt. el.heater No
Lower el.heater Yes
Max power el.heaters kW 18
Define Cooling
Cooling No
Condense pipe secured Yes
Room temp. cooling 25
Define SMS
Activate GSM? No
Level of signal -------
Phone number 1 46704130901
Phone number 2 ---------------
Hardware version 1 1
Software version 1 5