Technical data
53
CTC EcoZenith i550 Pro
For the property owner
9.4.3 Operation data solar panels
This menu shows information about solar panels (if
defined in the
Installer/Define system/Solar panels
menu).
Status Solar panel charge tank
Shows status for solar panels:
• Off
Solar panels are in operating mode Off.
• Solar panel charge tank
The solar panels are charging the Ecozenith’s tank
• Solar panel update. Vacuum
The solar panels are charging the hot water system.
• Solar panel charge ground source
The solar panels are charging the ground source.
From solar panels °C 68 (-99...99)
This shows the temperature of the flow supplied from
the solar panels (sensor B31).
To solar panels °C 60 (-99...99)
This shows the temperature of the flow supplied to the
solar panels (sensors B30).
Pump Panel % 46 (0...100)
This shows the current charge as a percentage of
maximum capacity for the pump (G30).
Pump Solar Charge % 46 (0...100)
This shows the current charge as a percentage of
maximum capacity for the pump (G32). Only displayed if
the solar panel is connected via a heat exchanger to the
EcoZenith.
Pump charge brine loop (On /Off)
This shows the operating mode for the pump (G31) for
recharging the bedrock.
Valve charging Brine loop (On /Off)
This shows the mode for the valve (Y31) for recharging
the bedrock.
16 20 0 4 8 12
T ºC
60
40
20
0
-20
35°C
40°C
50°C
35°C
Operation
Active heat sources:
Heat pump, nbr of 1 (2)
Electric heater, kW 6.0 + 0.0
Solar
Wood
Ext Boiler
Cooling
Operation EcoZenith
Stored oper data
Heating circuit
Detailed oper data
Settings for heat pump id A1
Total operation time h: 149
Maximum primary fl ow °C: 51
Electric Heat kWh
Operating time h HP 1
Operating time/24h HP1
Starts/24h HP1
Stored oper data
Detailed oper data
Tank upper °C 60 (60) (40)
Tank lower °C 40 (43)
DHW tank ext °C 50
Ext. Buffer tank upper 70
Ext. Buffer tank lower 40
Current draw A 20
Add heat primary fl ow °C 45
Wood boiler °C 78
Flue gas wood boiler °C 100
Pool °C 12 (35)
Operation data heating
Out Room1 Prim.fl ow1 Return Room2 Prim.fl ow2
Status heat pump
Id Product Status
A1 EcoPart On, upper tank
A2 EcoPart On, lower tank
Select ID and OK for HP start
Operation data heat pump
Compressor On
Charge pump On 78%
Brine pump On
Brine in/out °C 4 / 1
Fan speed On/48%
HP in/out °C 35/42
Outside temp. °C 3
Current L1 9.8
Operation data solar panels
Status Solar panel charge tank
Outlet °C 68
Inlet °C 60
Pump Panel % 46
Pump Solar Charge % 46
Pump charge brine loop Off
Valve charging brine loop Off
Heating circuit
Primary fl ow 1°C 37 (38)
Return fl ow °C 20
Heating circ pump On
Mixing valve Open
Primary fl ow 2°C 34 (35)
Heating circ pump 2 Off
Mixing valve 2 Close
Room temp 3°C / Room temp cooling °C 32 (32)
Primary fl ow 3°C / Primary fl ow cooling °C 28 (29)
Heating circ pump 3 / Pump cooling Off
Mixing valve 3 / Mixing valve cooling Close