9.4.2.2 Operation data heat pump
This menu is intended for servicing and advanced
troubleshooting, and displays information about the heat
pump that has been selected from the previous menu
(“Heat pump status”).
Compressor On (On/Off)
Shows whether the compressor is operating or not.
Charge pump On/78% (On/Off/0 to 100)
Shows the charge pump’s operational status and flow
as a percentage.
Brine pump On (On/Off)
Indicates whether the brine pump is on or off. Shown for
EcoPart heat pumps.
Brine in/out °C 4/1 (-99...99)
This shows the brine pump’s incoming and outgoing
temperatures. Shown for EcoPart heat pumps.
Fan speed On/48% (On/Off/0 to 100)
This shows the heat pump’s operational status and
the fan speed as a percentage. Shown for EcoAir heat
pumps.
HP in/out °C 35/42 (0 to 99/0 to 99)
This shows the heat pump’s return and primary flow
temperatures.
Outside Temp °C 3 (-50...50)
Shows the outside temperature (sensor B15). Shown for
EcoAir heat pumps.
Current L1 9.8 (0.0 to 50.0)
Show the current for phase L1 to the compressor.
Phases 2 and 3 are not measured in the product.
16 20 0 4 8 12
T ºC
60
40
20
0
-20
35°C
40°C
50°C
35°C
Operation
Active heat sources:
Heat pump, nbr of 1 (2)
Electric heater, kW 6.0 + 0.0
Solar
Wood
Ext Boiler
Cooling
Operation EcoZenith
Stored oper data
Heating circuit
Detailed oper data
Settings for heat pump id A1
Total operation time h: 149
Maximum primary fl ow °C: 51
Electric Heat kWh
Operating time h HP 1
Operating time/24h HP1
Starts/24h HP1
Stored oper data
Detailed oper data
Tank upper °C 60 (60) (40)
Tank lower °C 40 (43)
DHW tank ext °C 50
Ext. Buffer tank upper 70
Ext. Buffer tank lower 40
Current draw A 20
Add heat primary fl ow °C 45
Wood boiler °C 78
Flue gas wood boiler °C 100
Pool °C 12 (35)
Operation data heating
Out Room1 Prim.fl ow1 Return Room2 Prim.fl ow2
Status heat pump
Id Product Status
A1 EcoPart On, upper tank
A2 EcoPart On, lower tank
Select ID and OK for HP start
Operation data heat pump
Compressor On
Charge pump On 78%
Brine pump On
Brine in/out °C 4 / 1
Fan speed On/48%
HP in/out °C 35/42
Outside temp. °C 3
Current L1 9.8
Operation data solar panels
Status Solar panel charge tank
Outlet °C 68
Inlet °C 60
Pump Panel % 46
Pump Solar Charge % 46
Pump charge brine loop Off
Valve charging brine loop Off
Heating circuit
Primary fl ow 1°C 37 (38)
Return fl ow °C 20
Heating circ pump On
Mixing valve Open
Primary fl ow 2°C 34 (35)
Heating circ pump 2 Off
Mixing valve 2 Close
Room temp 3°C / Room temp cooling °C 32 (32)
Primary fl ow 3°C / Primary fl ow cooling °C 28 (29)
Heating circ pump 3 / Pump cooling Off
Mixing valve 3 / Mixing valve cooling Close