Technical data
42
CTC EcoZenith i550 Pro
General Information
9. Detail Description Menus
All settings can be configured directly on screen using
the straightforward control unit. The large icons operate
as buttons on the touch display.
Operational and temperature information is also displayed
here. You can easily enter the different menus to find
information on the operation or to set your own values.
9.1 Start menu
This menu is the system’s start menu. This provides an
overview of the current operational data. The system
returns to this menu if no buttons are pressed within
ten minutes. All other menus can be accessed from this
menu. The display switches to screensaver mode after
approx. ten minutes. Touch the screen to wake it up.
Room temp.
Heating system settings for raising or lowering
the temperature indoors and for scheduling
temperature changes.
DHW
Settings for DHW production.
Operation
This shows current and historical operational
data for the system.
Installer
This is where the installer configures the
settings and service for your system.
1 2
Room temperature heating system 1
If room sensor 1 is defined, the room
temperature in question is displayed here.
1 2
Room temperature heating system 2
If room sensor 2 is defined, the room
temperature in question is displayed here.
Tank temperature
This shows the current water temperature in
the upper tank.
Outdoor temperature
This displays the current outdoor
temperature.
Home
The Home button takes you back to the Start
menu.
Return
The Return button takes you back to the
previous menu level.
OK
The OK button is used to mark and confirm
text and options in the menus.
Night reduction
This schedules a temperature reduction at
night if selected.
Holiday
This is used to reduce the room temperature
permanently, e.g. during holidays when the
house is unoccupied.
Weekly program
This is used to reduce the temperature for a
few days, for instance if you commute every
week.
Time/Language
This is used to set the date, time and the
language you want the menu to be displayed
in.
Settings
The settings for all heat pumps and operation
of the system are usually configured by the
installer.
Define system
This is used to adjust/modify the system’s
structure.
Service
Installer settings. These are configured by the
appropriate technical person.
22,2 ºC 21,2 ºC 58 ºC -5 ºC
1
2
1 2
1 2
1 2
3
35°C
40°C
50°C
35°C
Room temp. DHW Operation Installer
CTC EcoZenith i550 Pro Tuesday 08:45
Weekly schedule
Hot water
Operation
Installer
Time/Language Settings Defi ned system Service
Software display PCB: 20130530 v116
Software HP PCB: 20130503
Night reduction Holiday
Heating circuit 2
Heating circuit 1
Room temp.
22.3ºC (23.5)ºC
22.4ºC (23.5)ºC
Extra
hot water
0.0 hours
Off
Temperature
Normal