Specifications

D 6
Group 5: Multi-Step Speed and PLC Parameters
Factory
Parameters Explanation Settings Default
Setting
05-00 1st Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-01 2nd Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-02 3rd Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-03 4th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-04 5th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-05 6th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-06 7th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-07 8th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-08 9th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-09 10th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-10 11th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-11 12th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-12 13th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-13 14th Step Speed Freq. 0.00 to 400.00 Hz 0.00
05-14 15th Step Speed Freq. 0.00 to 400.00 Hz 0.00
d0: Disable PLC Operation
d1: Execute one program cycle
d2: Continuously execute program cycles
05-15 PLC Mode d3: Execute one program cycle step by step 00
d4: Continuously execute one program
cycle step by step
05-16
PLC Forward/ Reverse
Motion
00 to 32767 sec (0:FWD 1:REV) 00
05-17 Time Duration Step 1 00 to 65500 sec 00
05-18 Time Duration Step 2 00 to 65500 Sec 00
05-19 Time Duration Step 3 00 to 65500 Sec 00
05-20 Time Duration Step 4 00 to 65500 Sec 00
05-21 Time Duration Step 5 00 to 65500 Sec 00
05-22 Time Duration Step 6 00 to 65500 Sec 00
05-23 Time Duration Step 7 00 to 65500 Sec 00
05-24 Time Duration Step 8 00 to 65500 Sec 00
05-25 Time Duration Step 9 00 to 65500 Sec 00
05-26 Time Duration Step 10 00 to 65500 Sec 00
05-27 Time Duration Step 11 00 to 65500 Sec 00
05-28 Time Duration Step 12 00 to 65500 Sec 00
05-29 Time Duration Step 13 00 to 65500 Sec 00
05-30 Time Duration Step 14 00 to 65500 Sec 00
05-31 Time Duration Step 15 00 to 65500 Sec 00
APPENDIX D: ZVD Summary of Default Program Codes