Specifications

D-5
Group 4: Input Function Parameters
Factory
Parameters Explanation Settings Default
Setting
04-00 Potentiometer Bias
Frequency
0.0 to 350 Hz 0.0
04-01 Potentiometer Bias d0: Positive Bias
Polarity d1: Negative Bias
0
04-02 Potentiometer Frequency
Gain
1 to 200 % 100
04-03 Potentiometer Reverse d0: Forward Motion Only
Motion Enable d1: Reverse Motion Enabled 0
d2: Forward and Reverse Motion Enable
04-04 Multi-Function Input d0: Parameter Disable 0
Terminal 1 (MI0, MI1) d1: Multi-Step Speed Command 1 1
04-05 d2: Multi-Step Speed Command 2 2
Multi-Function Input d3: Multi-Step Speed Command 3 3
Terminal 2 (MI2) d4: Multi-Step Speed Command 4 4
04-06 Multi-Function Input d5: Reset 5
Terminal 3 (MI3) d6: Accel/Decel Speed Inhibit
d7: First or Second Accel/Decel Time
04-07 Multi-Function Input Selection
Terminal 4 (MI4) d8: Third or Forth Accel/Decel Time
Selection
04-08 Multi-Function Input d9: External Base Block (N.C) Input
Terminal 5 (MI5) d10: External Base Block (N.O) Input
d11: Increase Master Frequency
04-09 Multi-Function Input d12: Decrease Master Frequency
Terminal 6 (MI6) d13: Counter Reset
d14: Run PLC Program
6
d15: Pause PLC
d16: Auxiliary Motor No.1 Output Failure
d17: Auxiliary Motor No.2 Output Failure
d18: Auxiliary Motor No.3 Output Failure
d19: Emergency Stop (NO)
d20: Emergency Stop (NC)
d21: Analog Output Frequency AVI/ACI
d22: Analog Output Frequency AVI/AUI
d23: Operation Command
Keypad/external Terminal
d24: Auto/Linear Accel/Decel Selection
04-10 Digital Terminal Input Delay Time d01 to d20m sec 01