Technical data
W.E.ST.
Elektronik GmbH
Page 18 of 25 PAM-190-P-*-1021 01.12.2014
5.2.4 LIM (Signal monitoring)
Command
Parameters
Unit
Group
LIM X
x= 0… 2000
0,01%
EXP
The signal monitoring is used to check the input signal - after the scaling function - whether the signal is inside
of the defined lower/upper area. Usable - for example - to detect a cable break down of joysticks.
Example:
LIM 500 (5% lower/upper limitation)
If the input signal is > 95% or < 5% then the signal is outside of the working area. The reason could be a short
cut or a cable break down. The power stage will be switched off.
5.2.5 R (ramp times)
Command
Parameters
Unit
Group
R:UP X
R:DOWN X
x= 50… 10000
x= 50… 10000
ms
ms
STD
This parameter is specified in ms.
The ramp time is separately set for UP and DOWN.
t
Ausgang/Output A
R:UP
R:DOWN