Technical data
W.E.ST.
Elektronik GmbH
Page 15 of 25 PAM-190-P-*-1021 01.12.2014
5 Parameters
5.1 Parameter list
Command
Default
Unit
Description
LG
EN
-
Changing language help texts.
MODE
STD
-
Mode parameter (standard or expert).
AIN:I
A
B
C
X
1000
1000
0
V
-
Free scaling of the analogue input signal.
Caution: V|C (Current / Pressure switchover is
deactivated)
LIM
0
0.01%
Signal overview function.
R:UP
100
ms
Ramp UP time for 100% of the input signal
R:DOWN
100
ms
Ramp DOWN time for 100% of the input signal
MIN
0
0.01%
Zero point setting, deadband compensation.
MAX
10000
0.01%
Maximum output signal limitation.
TRIGGER
200
0.01%
Trigger threshold for activating the following error
compensation (MIN).
POL
+
-
Reversal of output polarity.
CURRENT
0
-
Output current range: 0= 1,0 A / 1 = 2,5 A
DAMPL
0
0.01%
Dither amplitude.
DFREQ
120
HZ
Dither frequency.
PWM
488
HZ
PWM frequency
PPWM
1
-
Current control loop PI control dynamics.
IPWM
40
-
Current control loop PI control dynamics.