Technical data

W.E.ST.
Elektronik GmbH
Page 14 of 25 PAM-190-P-*-1021 01.12.2014
4.6 Technical data
Power supply
Current consumption
External fuse
[VDC]
[mA]
[A]
12… 30 (incl. ripple)
< 50 + solenoid current
3 medium time lag
Reference voltages
[V]
8 ( maximum 10 mA) in W-version
Analogue inputs (sensor and command
signals)
Resolution
[V]
[mA]
[%]
0… 10; 90 kOhm
4...20; 240 Ohm
< 0,1 (intern 0,02) incl. oversampling
PWM Output current
PWM frequency
[A]
[Hz]
1 or 2,5 (per software selectable)
60...2500
Sample time (pressure control)
Sample time (solenoid current control)
[ms]
[ms]
1
0,167
Interface
LIN bus, 19200 Baud,
Housing
Hirschmann GDME
DIN EN 175 301-803-A
Protection class
Temperature range
Storage temperature
[°C]
[°C]
IP65 (with gasket)
-20… 65 (consider the current range)
-20 …70
Connections
M12, 5-pole (DESINA standard)
Weight
[kg]
0,110
EMC
EN 61000-6-2: 8/2002
EN 61000-6-3: 6/2005