Low Level Below
Low Level Below determines where the shift between green and blue happens in the
outer ring. It indicates to the engineer that level is now at risk of being below the noise
floor.
Peak Indicator
Range: -3 to +12 dBFS
With the Peak indicator you set at which level the red peak indicator in the top of the
meters is invoked.
Show PPM
Options: On/Off
If you use the Radar page as standard you may find the flickering meters visually
disturbing. This option allows you to turn the PPM meters on/off.
Auto Pause
On/Off - When ‘on’, meassuring will follow the host and meassure only while the host
is running.
Note:
NotallhostssupportstheLM6’sAutoPausefunction.IfLM6isinsertedinahostthat
does not supprt the Auto pause function the option is greyed out.
Loudness Unit Name
Choose between LKFS and LUFS depending on preference and region. LKFS is
typically used in USA and LUFS is typically used in Europe. LKFS refers to loudness
units on an absolute scale and is equal to LUFS.
Log (LM6 only)
A new Log file is created every time the plug-in is opened. The Log file includes
information such as:
-whenLM6wasopened
-howlongLM6timeLM6measuredmaterialsinceitwasopenedlast
-LoudnessRangeandProgramloudnessdatasincelasttimeLM6wasopened
The log file is saved in the path set under Log File Folder. To set the log file folder.
Double-click in the log File Folder field and navigate using the computers Finder/
Explorer
Reveal
Press Reveal to navigate directly to the filder specified in the Log File Folder field.