CHLORINATOR MAINTENANCE
Chlorinator Maintenance
How to clean your cell.
In unusual situations, the self cleaning electrodes may benefit from occasional manual cleaning
to remove scale build-up as the result of having very “hard” water or continuous high pH
conditions, which can occur with new plaster finishes.
1. Switch off the filter pump and chlorinator, close necessary valves.
Note:Always turn pump off prior to installing or removing any Clearwater Cell.
Your pump/filter system is operated under pressure and pressure must be released
before you begin. Open the air relief valve on your pool filter to release the
pressure in the system.
2. Unplug the leads from the cell terminals.
3. Undo the two barrel unions joining the cell housing to the pool filtration system and
carefully remove the cell housing. Lay the housing upside down on a flat surface with the
inlet ports on top.
Chlorinator Maintenance
(Continued on next page)