Starting up (see fig. 2)
Move the gas control slide to the ignition position. Observe the pilot burner. Press in the
central button of the control slider and hold depressed while pushing the Piezo igniter
button two or three times. The pilot should light. Wait approximately twenty seconds and
then release the centre button of the control slider.
The pilot should remain alight. If the pilot does not light, repeat the operation until a flame
is established.
Note: On initial light up, or after any prolonged shut down, the pilot may take several
attempts to establish due to the presence of air in the gas supply system.
Fig. 2
G661_013
Gas control slide - ignition position
G661_012
Gas control slide - output control (see fig. 3)
After successful ignition move the slide control to the right positioning it according to your
output requirement. The further to the right you position the slide control the higher the
output, and consequently the higher the consumption of gas.
Maximum output is obtained when the slide control is to the far right.
In order to optimize energy consumption, adjust slide control position to supply the