Technical data

See Fig. 2 and 3.
The Data Plate is fixed to the top of the control box casing.
VERTICAL BALANCED FLUE.
Instructions describing the fitting of the vertical balanced flue
system are sent with the vertical flue kit.
IMPORTANT: It will be necessary to purchase at least one 90°
flue bend when installing the vertical balanced flue system. See
Section 5b “Flue Options” for further information.
NOTE: The maximum overall height of the vertical balanced flue
measured from the top of the appliance casing to the top of the
vertical balanced flue terminal is 5500 mm.
3. Technical Data
5
NOMINAL BOILER RATINGS (10 minutes after lighting the appliance)
MODE OUTPUT INPUT
BURNER SETTING
GAS RATE
PRESSURE
kW Btu/h kW Btu/h m bar. in. wg. m
3
/h ft
3
/h
8.8 (30,000) 12.1 (41,300) 1.0 0.4 1.11 40.0
11.0 (37,000) 15.0 (51,000) 3.5 1.4 1.45 51.0
13.0 (44,350) 17.4 (59,400) 5.2 2.1 1.55 54.5
HEATING 15.0 (51,200) 19.7 (67,000) 5.5 2.2 1.90 67.5
RANGE 17.0 (58,000) 22.2 (75,700) 7.5 3.0 2.15 76.0
19.0 (64,800) 24.5 (83,500) 9.5 3.8 2.40 84.0
21.0 (71,500) 27.0 (92,000) 11.0 4.4 2.60 92.5
23.0 (78,500) 29.2 (99,500) 14.0 5.6 2.80 100.0
24.0 (82,000) 30.0 (102,000) 14.5 5.8 2.90 102.0
HOT WATER 24.0 (82,000) 30.0 (102,000) 14.5 5.8 2.90 102.2
Table 1
VERTICAL BALANCED FLUE DETAILS
mm inches
CEILING HOLE DIAMETER 130 5.0
MINIMUM AIR DUCT LENGTH 100 4.0
MAXIMUM AIR DUCT LENGTH 4500 177.0
Table 3
FLUE DETAILS
mm inches
WALL HOLE DIAMETER 120 4.5
WALL HOLE DIAMETER FOR OPTIONAL EXTRA INTERNAL FLUE FIXING KIT 150 6.0
STANDARD HORIZONTAL FLUE MINIMUM LENGTH SIDE AND REAR 100 4.0
STANDARD HORIZONTAL FLUE MAXIMUM LENGTHS REAR 500 19.6
SIDE 1000 39.3
EXTENDED HORIZONTAL FLUE MAXIMUM LENGTH SIDE AND REAR 3000 118
Table 2: Multi-Directional Flue System.
NOTE: The appliance is factory pre-set to satisfy a central heating requirement of 15 kW (51,200 Btu/h). The output must be adjusted to
suit the heating system when commissioning the appliance.
NOTE: 1. THE STANDARD HORIZONTAL REAR FLUE KIT IS SUITABLE FOR REAR FLUE APPLICATION ONLY. A FLUE ADAPTOR IS INCLUDED IN
THE KIT.
NOTE: 2. THE STANDARD HORIZONTAL SIDE FLUE KIT IS SUITABLE FOR SIDE FLUE APPLICATIONS ONLY. A 90° FLUE BEND IS INCLUDED IN
THE KIT.
NOTE: 3. OPTIONAL EXTRA FLUE BENDS ARE AVAILABLE. THE MAXIMUM FLUE LENGTH IS REDUCED WHEN AN EXTRA FLUE BEND OR
BENDS ARE USED. Refer to Note 4 and 5.
NOTE: 4. WHEN USING TWO FLUE BENDS THE MAXIMUM EXTENDED STRAIGHT FLUE LENGTH MUST NOT EXCEED 2300 mm.
NOTE: 5. WHEN USING THREE FLUE BENDS THE MAXIMUM EXTENDED STRAIGHT FLUE LENGTH MUST EXCEED 1000 MM .
NOTE: 6. SEE SECTION 5b “FLUE OPTIONS” FOR FURTHER INFORMATION.
NOTE: 7. NO MORE THAN THREE 90° FLUE BENDS CAN BE USED.