Technical data
ii) A flue restrictor ring may be required. Refer to
Section 11.3 to determine the size or whether
the restrictor is necessary.
iii) A flue adaptor MUST be fitted to connect the
flue system to the appliance. Refer to the
instructions in Section 11.4.
Horizontal section of flue duct from the rear of the appliance
casing to the first 90° flue bend.
25
Fig. 21. Fixing the flue terminal and flue adaptor
to the air duct, flue duct and flue position
located on the rear of the inner casing for rear
flue applications.
Drill through the holes in the flue
terminal into the air duct. Apply a
smear of silicone sealant to this
joint. Fix together with the screws
provided.
Apply a smear of silicone sealant
to both joints. Fix the air and flue
duct to the flue adaptor with the
screws provided. Ensure that the
air and flue ducts are located
correctly in the flue adaptor.
Ensure the holes in the air and
flue ducts are next to the flue
adaptor
Do not apply silicone
sealant to the inner joints
Flue terminal
Clamping screw
accessible on top of
the inner casing
Top of appliance inner casing
View on top of appliance
Do not apply silicone
sealant to this joint
Flue restrictor ring
Flue adaptor
Flue position located
on rear of inner
casing
Rear of appliance
Drill through the holes in the flue terminal into
the air duct. Apply a smear of silicone sealant to
this joint. Fix together with the screws provided.
Apply a smear of silicone
sealant to both joints. Fix
the air and flue duct to the
flue bend with the screws
provided. Ensure that the
air and flue ducts are
located correctly in the flue
bend.
Flue terminal
Clamping screw
accessible on top of
the inner casing
Top of appliance inner casing
Top of appliance inner casing
View on top of appliance
Do not apply silicone
sealant to this joint
Do not apply silicone
sealant to these joints
Align the flue bend with the
flue location and fix in
position with the clamping
screw
Flue restrictor ring
Rear of appliance
Rear of appliance
Flue
bend
Fig. 22. Fixing the flue terminal
and the flue bend to the air duct,
flue duct and flue position,
located on the rear of the inner
casing for side flue applications.