Technical data

77
Controls
The Worcester Greenstar FS CDi Regular fascia incorporates
a combined temperature control and burner reset button.
The fascia also displays 2 operational status neons
indicating the following:
Mains on/lockout
Burner on.
The mains on/lockout indicator also operate as fault finding
diagnostics flashing in different sequences in the unlikely
event of a boiler fault.
The Building Regulations Section L 2006 require a minimum
level of controls to be installed on all heating systems, both
on new build and refurbishment.
This would require:
Room thermostat
TRVs on all radiators, or at least those radiators in
sleeping areas if not already fitted. Do not fit TRVs in the
room in which the room thermostat is installed
Time and temperature control for central heating
Automatic by-pass.*
*Where requested – see installation booklet for further details.
Applications
Greenstar FS CDi Regular boilers are suitable for a wide
range of heating loads allowing extension to the heating
system without upgrading the boiler
The Greenstar FS CDi Regular is capable of operating on
both open vent and sealed primary water systems
Two or more Greenstar FS CDi Regular boilers can be
linked together to cater for commercial or industrial
applications
Using the new flexible flue system the Greenstar FS CDi
is an ideal replacement for a floor standing boiler located
near a fireplace and using a chimney liner to flue.