Technical data
77
Controls
The Worcester Greenstar FS CDi Regular fascia incorporates
a combined temperature control and burner reset button.
The fascia also displays 2 operational status neons
indicating the following:
•
Mains on/lockout
•
Burner on.
The mains on/lockout indicator also operate as fault finding
diagnostics flashing in different sequences in the unlikely
event of a boiler fault.
The Building Regulations Section L 2006 require a minimum
level of controls to be installed on all heating systems, both
on new build and refurbishment.
This would require:
•
Room thermostat
•
TRVs on all radiators, or at least those radiators in
sleeping areas if not already fitted. Do not fit TRVs in the
room in which the room thermostat is installed
•
Time and temperature control for central heating
•
Automatic by-pass.*
*Where requested – see installation booklet for further details.
Applications
•
Greenstar FS CDi Regular boilers are suitable for a wide
range of heating loads allowing extension to the heating
system without upgrading the boiler
•
The Greenstar FS CDi Regular is capable of operating on
both open vent and sealed primary water systems
•
Two or more Greenstar FS CDi Regular boilers can be
linked together to cater for commercial or industrial
applications
•
Using the new flexible flue system the Greenstar FS CDi
is an ideal replacement for a floor standing boiler located
near a fireplace and using a chimney liner to flue.