Technical data
1515
Air supply
The Worcester Greenstar FS CDi Regular is a room sealed 
appliance; the room in which it is installed does not 
therefore require a purpose provided combustion air vent.
Natural gas supply
The appliances when on full output demand will require up 
to 3.27m
3
/h (FS 30CDi) or 4.4m
3
/h (FS 42CDi) of gas. The 
gas meter and supply pipes must be capable of supplying 
this quantity of gas in addition to the demand from any 
other appliance being served. Under no circumstances 
should the size of the gas supply pipe be less than that of 
the appliance inlet connection (22mm diameter). The meter 
outlet governor should be capable of ensuring a dynamic 
nominal pressure of 20mbar (8in wg) at the appliance. 
Particular consideration should be given to the resistance 
to gas flow created by elbows, bends etc. Pipework should 
be sized to overcome this resistance, and details of this are 
given in the following table.
Liquid Petroleum Gas (LPG) supply
The Greenstar FS CDi Regular appliance is available in an 
LPG version. The appliance, when on demand at full output 
will require 2.3kg/h for the FS 30CDi Regular and 3.3kg/h 
for the FS 42CDi Regular.
The gas tank or bottles must be capable of supplying this 
quantity of gas at a nominal pressure of 37mbar (14.8in wg) 
at the appliance. The table below shows the LPG discharge 
through varying lengths of pipe and the resistance to flow 
created by elbows, bends etc. Pipework should be sized to 
overcome this resistance.
Electricity supply
A 3 amp fused three pin plug and unswitched shuttered 
socket outlet (both complying with BS 1363) or preferably a 
double pole isolator with a contact separation of 3mm in all 
poles supplying the appliance should be used.
The appliance electrical circuits are also protected by an 
internal 2.5 amp fuse. The appliance must be earthed.
Guarantee
Worcester Greenstar FS CDi Regular appliances are offered 
with a full 2 year guarantee* on parts and labour, a 10 year 
guarantee* on the primary heat exchanger and a 5 year 
guarantee* on the plate heat exchanger. Ongoing service 
and maintenance contracts can be arranged through the 
Worcester Customer Service Department.
Please contact our guarantee registration advisors on  
0844 892 2552 or visit www.worcester-bosch.co.uk/
guarantee
Elbows or tees
  Metres  Feet
  0.6  2
90º bends
Metres  Feet
0.3  1
Approximate additional length to be allowed (LPG)
   Total length of   Pipe diameter 
  gas supply pipe (m)  (mm)
  3  6  9  –
 Gas
1.5  1.01  –  15
discharge
8.0  5.2  4.2  22
rate m
3
/h
15.9  8.9  8.3  28
   Total length of   Pipe diameter 
  gas supply pipe (m)  (mm)
  3  6  9  –
 Gas
2.9  –  –  15
discharge
8.7  5.8  4.6  22
rate m
3
/h
18.0  12.0  9.4  28
Elbows or tees
  Metres  Feet
  0.5  2
90º bends
  Metres  Feet
  0.3  1
Approximate additional length to be allowed (natural gas)
*Subject to conditions.