Installation manual
SERVICING AND SPARES
8 716 115 519a (2009/03)26
6 SERVICING AND SPARES
6.1 SERVICING
To perform the visual check of the flue system:
1. Rotate and remove the end cover from the tee piece.
2. Unscrew and remove the inner flue end cover
3. Remove the screws that secure the inspection plate
and slide the inspection plate away from the chimney.
Replace all end covers and the inspection plate after
visual inspection of the flue system.
Fig. 41 Performing the visual check
An annual visual check of the flue system
must be performed.