Installation manual
INSTALLATION
8 716 115 519a (2009/03)18
The flexible flue must now be prepared so the terminal
adaptor can be fitted.
6. Cut the flexible liner three complete corrugated
sections above the support collar.
Ensure to cut at the bottom of the wide recess
directly above the corrugated section.
7. Grease the seal.
8. Fit the seal into the first wide recess on the flexible
liner. Make sure the seal is not twisted and is seated
properly.
Fig. 23 Cutting flexible liner and fitting seal
To reinforce the end of the flexible liner:
9. Fit the liner into the flexible liner.
Fig. 24 Fitting the liner into the flexible liner
The terminal adaptor can now be fitted to the flexible
liner.
10. Push the terminal adaptor onto the flexible liner
until it “bottoms out” and the movable band “clicks”
into place.
If the band does not “click” into place, check:
B the adaptor is pushed down fully
B the adaptor is square to the flexible liner
B the lugs are aligned with their slots in the adaptor
B that the flexible liner is cut correctly
11. Rotate the movable band anti-clockwise until it locks
in place.
12. Grease the adaptor seal.
Fig. 25 Fitting the terminal adaptor
B Refer to pages 13 and 14 for additional
information on how to prepare the
terminal adaptor.