USER INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER GREENSTAR CDi CLASSIC SYSTEM ErP INDIRECT FED DOMESTIC HOT WATER 6 720 812 179-00.1O The appliance is for use with: Natural Gas or L.P.G. (CAT II 2H3P type C13 & C33) Natural Gas: 30CDi Classic System ErP GC number 41-406-37 35CDi Classic System ErP GC number 41-406-39 L.P.
Preface PREFACE PLEASE READ THESE INSTRUCTIONS CAREFULLY These instructions are applicable to the Worcester, Bosch Group boiler model stated on the front cover only. These instructions apply in the UK/IE only and must be followed except for any statutory obligation. After installation please leave this User instruction Manual, Installation, Commissioning and Servicing Instructions and completed Benchmark Checklist with the user.
Key to symbols and safety instructions 1 KEY TO SYMBOLS AND SAFETY INSTRUCTIONS 1.1 KEY TO SYMBOLS WARNINGS Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. The following keywords are defined and can be used in this document: • NOTE indicates a situation that could result in damage to property or equipment.
Product details HANDOVER TO THE USER When handing over, instruct the user how to operate the heating system and inform him about its operating conditions. ▶ Explain how to operate the heating system and draw the user's attention to any safety-relevant action. ▶ Explain that modifications and repairs must only be carried out by an authorised contractor. ▶ Advise the user to have the system serviced annually by a competent, Gas Safe registered engineer.
Operating the boiler 3 OPERATING THE BOILER 3.1 CONTROLS 1 2 3 13 12 11 5 6 7 10 Fig. 1 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] 4 9 8 6 720 812 178-01.
Operating the boiler 3.2 SWITCHING THE BOILER ON/OFF 1 6 720 812 178-02.1O Fig. 2 Switching on ▶ Switch on the boiler by pressing the ON/OFF button. The ON/OFF indicator light [1] shows blue. The boiler runs for 15 minutes at minimum heating output to fill the condensate trap. The display [K] alternates between and the central heating flow temperature. This occurs every time the mains supply has been interrupted. Switching off ▶ Switch off the boiler by pressing the ON/OFF button.
Operating the boiler 3.3 SETTING THE CENTRAL HEATING TEMPERATURE ▶ Turn the central heating temperature control to the desired level, between approximately 35 °C and 90 °C. When the burner is lit, the burner indicator light [1] underneath the ON/OFF button shows green. 1 min 6 720 812 178-03.1O Fig. 3 Position Central heating temperature 1 approx. 35 °C 2 approx. 43 °C 3 approx. 50 °C 4 approx. 60 °C 5 approx. 67 °C 6 approx. 75 °C max Table 2 approx.
Operating the boiler 3.4 SETTING THE HOT WATER TEMPERATURE (ONLY IN CONJUNCTION WITH OPTIONAL DIVERTER VALVE) 3 2 6 720 812 178-05.1O Fig. 4 ▶ Turn the domestic hot water temperature control [1] to the desired level, between approximately 40 °C and 60 °C. Position Hot water temperature min approx. 40 °C e approx. 50 °C max Table 3 8 approx.
Operating the boiler 3.5 FROST PROTECTION (IN CONJUNCTION WITH OPTIONAL DIVERTER VALVE) Activating frost protection will turn off the boiler and prevent heating of the central heating and domestic hot water cylinder. If the temperature within the boiler drops to 5 °C the boiler will fire to avoid the possibility of freezing. 1 6 720 812 178-04.1O Fig. 5 To activate frost protection: ▶ Leave ON/OFF button [1] on. ▶ Turn the central heating temperature control to 3.6 .
Operating the boiler 3.7 ECO MODE (ONLY IN CONJUNCTION WITH OPTIONAL DIVERTER VALVE) 6 720 812 178-06.1O Fig. 6 To deactivate eco mode: ▶ Press the eco button until it goes off. When the eco button is not illuminated the hot water cylinder has priority. The hot water cylinder is first heated up and then the appliance switches to central heating mode. To re-activate eco mode: ▶ Press the eco button until it lights up.
Operating the boiler 3.8 HOLIDAY SETTING (ONLY IN CONJUNCTION WITH OPTIONAL DIVERTER VALVE) 6 720 812 178-07.1O Fig. 7 To activate holiday mode: ▶ Press the holiday button until it lights up. When the holiday button lights up, central heating is switched off. Frost protection remains active. To deactivate holiday mode: ▶ Press the holiday button until it goes off. When the holiday button is not illuminated, the appliance runs in normal mode.
Operating the boiler 3.9 FAULT CONDITION In the event of a fault occurring while the boiler is in operation the reset button [2] and the fault indicator [3] will flash. The display [1] will show an error code (for error codes see table 5 on page 14). 1 2 3 6 720 812 178-08.1O Fig. 8 To reset the boiler: ▶ Press the reset button [2] for three seconds. The reset button [2] and the fault indicator [3] will stop flashing.
Maintenance 4 MAINTENANCE Your new Greenstar CDi Classic System ErP gas-fired appliance represents a long term investment in a reliable, high quality product. If you would like to know more about a Worcester Bosch service contract, please tick the appropriate box on your warranty registration card.
Maintenance 4.2 ERROR CODES When calling Worcester, Bosch Group, you may be asked for the error code. This Table is for you to help identify the possible cause of the fault. ▶ Do not try to rectify any of the faults listed below by yourself. ▶ Contact British Gas or a competent, qualified engineer (Gas Safe registered personnel). Error code Description b1 Code plug not detected. C6 Fan speed too low. E9 Safety temp. limiter in CH flow has tripped. EA Flame not detected.
General notes 4.3 EXTREME COLD WEATHER In some instances where the condensate pipe work is run externally or in an unheated area, such as a garage, the condensate pipe work can be at risk of freezing, even if well insulated. The Greenstar CDi Classic System ErPcontains a larger internal condensate siphonic trap, but care should be taken in the location of a condensate pipe. A frozen/blocked condensate pipe will cause the boiler to shut down.
Fault or Breakdown ▶ Do not restrict this space with the addition of cupboards, shelves etc. around or next to the boiler. VENTILATION This is a room sealed boiler and does not require any air for combustion from inside the property. If a compartment is built around the boiler after installation, then this must be carried out as described in the Installation Manual. CAUTION: Risk of damage to the boiler. ▶ Do not operate the boiler if the flue terminal is obstructed or damaged in any way.
Tips on energy saving 7 TIPS ON ENERGY SAVING HEATING ECONOMICALLY The boiler is designed to provide a level of comfort while keeping gas consumption and the resulting environmental effect as low as possible. The gas supply to the burner is controlled according to the level of demand for heat. The boiler continues to operate with a low flame if the demand of heat reduces. The technical term for this is modulating control.
Environment / disposal 8 ENVIRONMENT / DISPOSAL Environmental protection is a fundamental corporate strategy of the Bosch Group. The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed. We use the best possible technology and materials for protecting the environment taking account of economic considerations.
Glossary 10 GLOSSARY PLUMING AND CONDENSATE DRAIN This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This is quite normal. The boiler produces condensate which is discharged regularly by a syphon within the boiler via a plastic pipe to a drain. This pipe must not be blocked or altered in any way.