USER INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER GREENSTAR CDi CLASSIC REGULAR FOR OPEN VENTED AND SEALED CENTRAL HEATING SYSTEMS AND INDIRECTLY FED DOMESTIC HOT WATER 6 720 806 549 (2013/02) UK/IE
PREFACE PREFACE TABLE OF CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY These instructions are applicable to the Worcester, Bosch Group boiler model stated on the front cover only. 1 Key to symbols and safety instructions . . . 3 1.1 Key to symbols . . . . . . . . . . . . . . . . . . 3 1.2 General safety instructions . . . . . . . . 3 2 General Information . . . . . . . . . . . . . . . . . . . . 4 3 Operating the boiler . . . . . . . . . . . . . . . . . . . . 5 3.1 Controls . . . . . . . . . . .
KEY TO SYMBOLS AND SAFETY INSTRUCTIONS IF YOU SMELL GAS 1 KEY TO SYMBOLS AND SAFETY INSTRUCTIONS 1.1 KEY TO SYMBOLS WARNINGS Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken.
GENERAL INFORMATION HANDOVER TO THE USER When handing over, instruct the user how to operate the heating system and inform him about its operating conditions. ▶ Explain how to operate the heating system and draw the user's attention to any safety-relevant action. ▶ Explain that modifications and repairs must only be carried out by an authorised contractor. ▶ Advise the user to have the system serviced annually by a competent, Gas Safe registered engineer.
OPERATING THE BOILER 3 OPERATING THE BOILER 3.1 CONTROLS 10 9 8 7 reset eco 3 4 5 2 6 1 5 6 max Fig. 1 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] 2 3 4 6720806548-14.1Wo 1 Control panel Display Reset button Not used Not used ON/OFF and fault indicator (Blue) Central heating temperature control Performance test button Service button Burner indicator (Green) ON/OFF button 3.2 SWITCHING THE BOILER ON/OFF Switching on ▶ Switch on the boiler by pressing the power button [10].
OPERATING THE BOILER 3.3 SETTING THE CENTRAL HEATING TEMPERATURE ▶ Turn the central heating temperature control [6] to the desired level, between approximately 35°C and 90°C. ▶ When the burner is lit, the green indicator light [9] underneath the on/off switch is illuminated. 9 reset eco 3 2 6 1 4 5 6 max 6720806549-02.1Wo Position Central heating temperature 1 approx. 35°C 2 approx. 43°C 3 approx. 50°C 4 approx. 60°C 5 approx. 67°C 6 approx. 75°C max approx.
OPERATING THE BOILER 3.4 FROST PROTECTION (FOR THE BOILER) Activating frost protection will turn off the boiler and prevent heating of the central heating and domestic hot water cylinder. If the temperature within the boiler drops to 5°C the boiler will fire to avoid the possibility of freezing. 10 reset eco 3 2 1 6 4 5 6 max 6720806549-03.1Wo To activate frost protection: ▶ Leave power [10] switch on. ▶ Turn the central heating temperature control [6] to . 3.4.
OPERATING THE BOILER 3.5 FAULT CONDITION In the unlikely event of a fault occurring while the boiler is in operation the reset button and the main power indicator [5] will flash. The display [1] will show a fault code. 1 reset eco 3 2 1 2 4 5 6 5 max 6720806549-04.1Wo To reset the boiler: ▶ Press the reset button [2] for three seconds. The reset button [2] and the mains power indicator [5] will stop flashing. The boiler will function normally, dependent on programmer and room thermostat settings.
MAINTENANCE 4 MAINTENANCE 4.1 FAULT FINDING This table gives information on basic operating system problems. Problem Cause Remedy EA fault code flashing on display No gas supply/low gas supply pressure ▶ Contact your gas supplier. Condensate outlet blocked ▶ If it is safe to do so, check your condensate pipe outlet for blockages, such as ice or foreign objects. Flue blocked ▶ If it is safe to do so, check your flue outlet for damage or blockages.
MAINTENANCE 4.2 ERROR CODES When calling Worcester, Bosch Group, you may be asked for the error code. This Table is for you to help identify the possible cause of the fault. ▶ Do not try to rectify any of the faults listed below by yourself. ▶ Contact British Gas or a competent, qualified engineer (Gas Safe registered personnel). Error code Description b1 Code plug not detected. C6 Fan speed too low. E9 Safety temp. limiter in CH flow has tripped. EA Flame not detected.
GENERAL NOTES 4.3 EXTREME COLD WEATHER In some instances where the condensate pipe work is run externally or in an unheated area, such as a garage, the condensate pipe work can be at risk of freezing, even if well insulated. A frozen/blocked condensate pipe will cause the boiler to shut down. WARNING: Falling hazard! Failure to follow this guidance may result in personal injury. ▶ Only attempt to thaw a condense pipe that is at ground level, and that is easily accessible.
FAULT OR BREAKDOWN CAUTION: Risk of damage to the boiler. ▶ Do not operate the boiler if the flue terminal is obstructed or damaged in any way. 6 FAULT OR BREAKDOWN This boiler is supported in the UK and Eire by Worcester, Bosch Group. Specialist Service Engineers are available to attend a breakdown occurring on this boiler. Invoices for attendance and repair work carried out on this boiler by any third party will not be accepted.
TIPS ON ENERGY SAVING 7 TIPS ON ENERGY SAVING HEATING ECONOMICALLY DRAUGHTS The boiler is designed to provide a level of comfort while keeping gas consumption and the resulting environmental effect as low as possible. The gas supply to the burner is controlled according to the level of demand for heat. The boiler continues to operate with a low flame if the demand of heat reduces. The technical term for this is modulating control.
YOUR GUARANTEE 8 YOUR GUARANTEE This boiler has a guarantee against faulty materials or workmanship for a period of two years from the date of installation subject to the following terms and conditions: • During the period of this guarantee any components of the boiler which are proven to be faulty or defective in manufacture will be exchanged or repaired free of charge by Bosch Thermotechnology Ltd.
GLOSSARY 9 GLOSSARY Central heating systems All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be bled by releasing air through the bleed screw at the top of the radiator. Ask your installer to show you how this is done. This boiler is fitted to a sealed system. Should water leaks be found or if excessive bleeding is required, then a service engineer must be contacted to inspect the installation and rectify any fault.
WORCESTER, BOSCH GROUP: Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0844 892 9900 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk Document No.