Technical data
3
3. Technical Data
Fig. 1. Pipework dimensions inside the property (all dimensions are millimeters)
Table 1
SPECIFICATIONS
MODEL 12/19
POWER SUPPLY 230V 50Hz
HEATING FLOW 22mm
HEATING RETURN 22mm
HEIGHT 600mm
WIDTH 420mm
DEPTH 315mm standard (285mm optional)
FUEL LINE
1
/4 inch BSP
FLUE REQUIREMENT RS Telescopic (Supplied with appliance)
MAXIMUM STATIC HEAD 30m (98 ft.)
PRIMARY WATER CAPACITY 6.5 litres (1.4 gal)
WEIGHT (DRY) 76Kg (167lbs)
WEIGHT (WET) 82.5Kg (182lbs)
BURNER Electro Oil Inter B9C
WATER SIDE RESISTANCE 10°C Difference 40 mbar
WATER SIDE RESISTANCE 20°C Difference 10 mbar
EXIT FLUE GAS MASS FLOW 33kg/h
CONTROL THERMOSTAT RANGE 55°C minimum cut in to 82°C maximum cut out
CONTROL THERMOSTAT DIFFERENTIAL 5°C
HIGH LIMIT THERMOSTAT BREAK POINT 100 +0/-6°C
MANUAL RESET THERMOSTAT BREAK POINT 110 +0/-6°C
DUCT MANUAL RESET THERMOSTAT BREAK POINT 100 +0/-6°C
FROST THERMOSTAT RANGE 5°C cut in to 10°C cut out
28 Sec. Kerosene 0.4 60°ES 115 1.11 1.41 180 9.5 7.25 13.3 46,000 12 41,000
28 Sec. Kerosene 0.5 60°ES 105 1.38 1.75 200 10.5 8.5 16.6 56,000 15 51,000
28 Sec. Kerosene 0.5 60°ES 140 1.57 1.99 210 11 8.75 18.9 65,000 17 58,000
28 Sec. Kerosene 0.6 60°ES 125 1.76 2.23 230 11.5 9 21.1 72,000 19 65,000
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
12/19 Table 2. Electro Oil Inter B9C Burner (See Fig. 28)
Fuel** Nozzle
Pump
Pressure
(p.s.i.)
Fuel Flow
Rate
Flue Gas
Temp.
(°C)*
%CO
2
Approx.
Air
Setting
Appliance
Input
kW Btu/hr kW Btu/hr
Output
Kg/h l/h
* NOTE: The flue gas temperature is measured in the flue. The probe should be inserted to a depth of 150mm in the center of the flue. The temperature measured is not an absolute flue
gas temperature and is for general guidance purposes only! **NOTE: Class C2 28sec kerosene.
NOTE: The pump pressure given is for general guidance only as variations in nozzle output can be up to ± 15%. It is, therefore, essential that the air is adjusted to give the correct CO
2
value.
NOTE: The nozzle type used on 28 Sec. Kerosene outputs are nozzles calibrated specifically for use with 28 Sec. Kerosene which gives less variation in nozzle output than the standard
35 Sec. Gas Oil nozzles. However, if a 28 Sec. Kerosene nozzle is not available at servicing or commissioning it is appropriate to install a 35 Sec. Gas Oil nozzle providing the output, spray
angle and pattern of the nozzle is the same as the 28 Sec. Kerosene nozzle (e.g. 0.560°ES may be replaced with a 0.560°S).
100
288
26
236 (315mm Standard)
206 (285mm Optional)
RETURN
FLOW
FRONT VIEW
SIDE VIEW
WALL
26
To the inside
of the pipe
end stop