Technical data

25
Wall mounting
bracket
Fig. 24. Wall mounting bracket positions.
Wall Mounting
Bracket
Wall mounting
duct
Wall mounting
duct
(a) Standard 315mm Position
(b) Optional 285mm Position
(for fitting appliance within a 300mm unit)
Fig. 25. Wall mounting duct / external duct assembly.
'D' Shaped
grommets
Main harness
External
duct
Wall mounting
duct
Wall mounting
duct seal
1
1
3
3
4
3
X
1. Two location holes each side to fasten the wall
mounting duct to the external duct.
2. N
o
6 locking screws
3. Completely seal the joint on all four sides
between the wall mounting duct and the
external duct with the sealant provided.
4. External control box
Fig. 26. Baffle location.
Fig. 27. Insulation box rope seals.
Middle rope seal
Outer rope seal
Inner rope seal
2
2
3
Heat exchanger
Baffle retainer
Baffle
Gently pull here
(to take up the slack in the wall
mounting/external duct)
WARNING: It is imperative the main
harness inside the wall mounting/external
duct is not sagging. This will prevent the
main harness being trapped behind the
insulation box.