Operating instructions

8
LOCKOUT
A flame failure device is incorporated into the control system
of your boiler. So, should the flame fail for any reason, or should
ignition fail to initiate a satisfactory start, the boiler is automatically
locked out for safety. This lockout condition is indicated by a sig-
nal lamp located on the burner control box.
To cancel the burner lockout condition, remove the boiler
front cover and allow two minutes before pressing the illuminated
lockout reset button, which is mounted on the burner control box.
Provided the system is still calling for heat, the burner will then
operate and commence another start cycle.
Persistent lockout indicates a fault and an engineer should be
called, so do not attempt to repeatedly restart the boiler.
FUEL
Your Worcester Danesmoor pressure-jet boiler is set to burn
28-second kerosene fuel. Some appliances can be converted to
burn 35-second gas oil. If this conversion has been made your
installer will inform you.
PLEASE NOTE: Danesmoor room-sealed and conventional
low-level discharge appliances MUST NOT be used with 35-sec-
ond gas oil.