Instruction manual
TECHNICAL DATA
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18-18/25
8 718 681 134a (08.08)
5
TECHNICAL DATA
Central Heating
Primary water capacity (total) litres
Maximum static head metres
Minimum static head metres
Water side resistance (20°C difference) mbar
Max. permissible sealed system operating pressure bar
in accordance with WRAS guidelines
Flue
Exit flue gas mass flow kg/hr
Pipework connections
Fuel line (compression) mm
Flow mm
Return mm
Primary drain
Condensate (polypropylene) mm
Electrical
Electrical power supply voltage AC...V
Frequency Hz
Max. power consumption W
Thermostats
Boiler flow temperature range (cut in/cut out) °C
Control thermostat differential °C
Boiler high limit thermostat set point °C
Boiler manual reset overheat thermostat set point °C
Flue manual reset overheat thermostat set point °C
General Data
SEDBUK (Band A) %
Appliance protection rating (with fascia programmer) IP
Appliance protection rating (with programmer blanking plate) IP
Appliance weight (dry) kg
Lift weight kg
Emissions class for NOx and CO class
Typical NOx emission figures mg/kWhr
DESCRIPTION UNITS 12/18 18/25
APPLIANCE
INFORMATION
23
30
1
30
2.5
29
10
22
22
21.5
230
50
150
55/81
5
95
105
110
92.6
20
20
108.5
72
1
160
23
30
1
69
2.5
40
10
22
22
21.5
230
50
160
55/81
5
95
105
110
92.8
20
20
108.5
72
1
160
12mm hose connection