ELECTRICS
DANGER - 230V:
ISOLATE THE MAINS ELECTRICITY
SUPPLY BEFORE STARTING ANY
WORK AND OBSERVE ALL
RELEVANT SAFETY PRECAUTIONS.
Access to 230V connections:
1Remove the five electrical box rear cover
screws (A) and remove the cover.
2Release screws (B) from cable clamp (C).
Feed sufficient power cable (D) through the
cable clamp (C) and secure grip with
screws (B).
Separate the wires from the outer insulation and
strip the insulation to 6mm.
230V connections:
3Connect LIVE wire (Brown) to
terminal LI.
Connect NEUTRAL wire (Blue) to
terminal N.
Connect EARTH wire (Green/Yellow) to
the terminal .
Any external device connected to the
boiler must NOT have a separate supply.
See the following pages of electrical
diagrams for details of different systems.
External 230V programmer:
4 Remove the link from link block (E).
Connect wires as shown.
Optional Worcester 230V programmer:
5 Remove the four fascia mounting plate
screws (F) and remove the mounting plate
from the fascia.
Loosen the two retaining screws (G) and
remove the blanking plate (H).
Fit the programmer then retighten the
retaining screws (G).
Refit the mounting plate into the fascia and
refit the four screws (F).
Remove the link block (E).
Plug the programmer block ( J )into the
terminal block as shown.
*Move the orange wire from terminal 9 to
terminal 6 for a 3 port valve system.
Refit rear cover:
Refit the rear cover to the electrical box
and secure with screws (A).
*
ELECTRICS