Instruction manual

IMPORTANT: The boiler is not designed to
take the weight of the flue system, this must
be supported externally to the boiler.
Grease the vertical adaptor seal with the
solvent free grease supplied. Install the flue
following the instructions supplied with the flue.
1Refit the condensate trap (A)to the flue
manifold using the hose clip (B) . Then
re-fit the bracket (C) to the wall mounting
frame using the two screws provided (D).
Fit 21.5mmØ polypropylene pipework (E)
to the condensate trap flexible pipe (F)
using the fitting provided then terminate
the trap outlet to waste.
Ensure that the condensate pipework runs
away from the boiler at a constant fall of
50mm (min.) per metre.
Remove the flue cowl access door (G) by
undoing the 4 securing nuts (H).
Carefully pour 500ml of water into the flue
cowl to fill the condensate trap.
Check the water is draining away and the
condensate pipework joints are water
tight.
Refit the flue cowl access door.
IMPORTANT: The condensate trap must be
correctly filled to prevent the possibility of
potentially harmful flue products escaping
via the condensate pipework.
2 Re-fit the flow and return pipes at the boiler.
Connect the system pipework ( I ) to the
flow ( J ) and return (K) pipes on the wall
bracket. These are push fit connections
secured with spring clips (L).
CONDENSATE TRAP
1
2
500ml
A
B
H x4
D
A
G
CONDENSATE TRAP
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18-18/25
8 718 681 134a (08.08)
26
INSTALLATION
C
E
F
G
I
J
I
K
L