Technical data

19
Fig.18. Rear Panel Assembly.
Silencer outlet plate
Rear panel
Rear panel bracket
N.B. To prevent water ingress
blank off options not required.
Fire valve entry
Oil pipe entry
Fig.19. Oil Plate Fixing Hole Positions.
12mm
two pipe
option
10mm two pipe option
12mm
single pipe
option
10mm single pipe option
Blanked off
option
Fig.20. Fire Valve Plate.
N.B. The silencer outlet
plate can be fitted in two
positions, depending on
the boiler position within
the Outdoor Pack.
Choose the option
which lines the silencer
outlet plate hole
centrally with the
clamping collar on the
back of the boiler.
3. Open the main oil supply valve at the tank and check for any leaks.
4. Place a suitable container below the bulkhead fitting and
open the valve.
5. Draw off at least 2.5 litres of oil until a steady flow of clear
uncontaminated oil can be seen and turn off the isolating valve.
Note: This method may not be possible on some installations
where a sub-gravity system is used. Where this problem arises
bleed the system using the oil pump as described in Section 12
and remove and clean the oil pump filter to remove any debris
collected as a result of installation.
11.6 Replace the electrical control panel and boiler side panels
in reverse order to the removal procedure of Section 5 and
connect the electrical supply as described in Section 10.