Technical data
To gain access to the appliance remove the cabinet front and top
panel and place the facia and control box in the Service Position.
Refer to Fig.14.
NOTE: As the dry weight of the appliance is 96Kg, more than one
person will be required when moving the appliance.
When the appliance is flued to the rear ensure the flue position, on
the rear of the appliance, is directly in line with the hole in the wall.
For all other flue applications, the centre of the flue position on the
appliance must be in line with the centre-lines for the Rear Flue
position, previously marked. See Fig. 13.
Always support the appliance pipework when tightening.
SEALED SYSTEM.
Connect a 15 mm copper drain pipe to the relief discharge
connection at the rear of the appliance. Ensure that any discharge
does not fall onto electrical components or where it might be a
hazard to the user. Refer to Fig. 15.
OPEN VENT SYSTEM.
If the appliance is to used on an open vent system the expansion
vessel and flexible hose are not required. Remove from the bottom
manifold connection and discard. Fit the 22 mm copper vent pipe,
supplied as an optional extra, to this connection. See Fig. 18.
To access the open vent connection remove the pump head.
Withdraw the two securing clips from the pump body.
Ease the pump forwards about 10mm off the “O” ring seals. It is not
necessary to disconnect the electrical cable. The cable is
sufficient
to allow the pump head to rest on top of the appliance. Do not allow
the pump head to be suspended by the cable. See Figs. 18 and 46.
NOTE: INTERNAL FLUE FITTING KIT.
If the Internal Flue Fitting Kit is to be used refer to Section 11.7
describing the assembly of the flue components and fitting the
Internal Flue Kit.
11.3 GUIDE LINES FOR ALL FLUE OPTIONS.
INTRODUCTION.
Remove ALL packaging from the ducts, flue bend or bends and flue
terminal assembly.
Check the contents of the standard flue kit and extension flue kit or
kits against the respective packing list.
IMPORTANT: The air duct, flue duct and flue bend/bends are
manufactured from aluminium and must be handled with care.
MEASUREMENT AND CUT.
Measure and cut the air and flue ducts to length ensuring that the
cuts are square and free from burrs. Always check the dimensions
before cutting the duct.
Do not cut the expanded end of the extension ducts unless
instructed to do so.
FLUE ADAPTOR.
The air and flue ducts supplied with the standard flue kits must
connect to the flue adaptor or first flue bend. See Fig. 22 or 23.
The flue adaptor,supplied with the Standard Horizontal Rear Flue Kit,
must be fitted for Flue Option 1 and 3. See Fig. 19.
Other flue options, that require a horizontal section of flue duct
fitted directly to the rear of the appliance, must use the flue adaptor.
See Fig. 12. 9. The flue adaptor is available as an optional extra.
Flue Option 6.
Centre-line position for
horizontal duct
Flue Option 3.
Rear flue extension
centre point
position
Flue Option 5.
Side flue extension centre
point position. Mark to suit
installation
Flue Option 2.
Side flue centre point
position
Flue Option 4.
Side flue
extension centre
point position
Flue Option 8.
Rear flue upward
extension centre point
position. Mark to suit
the installation. Refer
to Flue Option 6
Flue Option 7.
Side flue centre point
position. Mark to suit
the installation. Refer
to Flue Option 5
Extend the vertical line
250mm approx. above the
position for the flue bend
600
Corner
Corner
715
600
94
94
Side flue application:
Draw a horizontal line from
the rear flue centre point
position in the appropriate
direction
Mark on the floor the base
outline of the appliance
ALL INSTALLATIONS
MUST BE COMMENCED
BY MARKING THIS
POSITION
Flue Option 1.
Rear flue centre
point position. For
all flue options
mark this position
Fig. 13. Marking the flue positions for all flue options.
17