100mm dia horizontal telescopic flue lengths with a
60mm dia plume management system
The maximum effective straight flue lengths (L) are stated
opposite for the relevant appliance together with the
minimum and maximum lengths (M) of the plume
management system connected, these lengths must not
be exceeded.
60mm dia plume management system
To ensure that the maximum total straight flue length along
the plume management route is not exceeded the following
should be added to dimension (M):
1,500mm for each extra 90º bend
750mm for each extra 45º bend
For plume management options with 60mm dia extensions
refer to pages 26 – 28.
Example, Greenstar 30CDi:
Required plume management length (M) is 2,500mm, which
is kit (500mm) plus 2 x 1,000mm extensions. Therefore,
flue length (L) must be reduced by 2 x 700mm, giving a
maximum allowed straight length (L) of:
Maximum possible straight flue length 7,000mm
Required length of plume management -2,500mm
Minus reduction factor of 2 x 700mm -1,400mm
Maximum available straight flue length 3,100mm
Option 1
Plume management system
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60mm Plume Management Kit 1 7 716 191 086
40CDi Conventional
60mm Plume Management Kit 1 7 716 191 086
30CDi System
60mm Plume Management Kit 1 7 716 191 086
*NOTE: You must refer to the table on page 25 to calculate
your horizontal flue lengths and plume management length.
Option 2
Plume management system with extensions
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
30CDi System
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
*NOTE: You must refer to the table on page 25 to calculate
your horizontal flue lengths and plume management length.
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
60mm 45º Bend 1 7 716 191 089
30CDi System
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
60mm 45º Bend 1 7 716 191 089
*NOTE: You must refer to the table on page 25 to calculate
your horizontal flue lengths and plume management length.
Option 3
Plume management system with extensions and 45º bend
Option 4
Plume management system with angled termination
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
30CDi System
60mm Plume Management Kit 1 7 716 191 086
60mm 1,000mm Extension up to 4 7 716 191 087
*NOTE: You must refer to the table on page 25 to calculate
your horizontal flue lengths and plume management length.
Maximum total straight plume length
60mm dia
30CDi Conventional 500mm*
40CDi Conventional 500mm*
30CDi System 500mm*
Maximum total straight plume length
60mm dia
30CDi Conventional 4,500mm*
40CDi Conventional N/A
30CDi System 4,500mm*
Maximum total straight plume length
60mm dia
30CDi Conventional 3,750mm*
40CDi Conventional N/A
30CDi System 3,750mm*
Maximum total straight plume length
60mm dia
30CDi Conventional 4,500mm*
40CDi Conventional N/A
30CDi System 4,500mm*
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 26