Technical data

2322
Greenstar CDi regular & system
boiler series vertical fluing options
The Greenstar CDi series have the choice of 2 differently
sized vertical RSF flue systems, 100mm and 125mm. Both
systems have different maximum lengths. Options 1 to 3
detail the permissible lengths.
Vertical RSF flue
Vertical balanced flue kit
Comprises:
1 x flue terminal assembly
1 x weather sealing collar
1 x fire stop spacer
1 x vertical adaptor
Part No. 7 719 002 430 (100mm dia)
Part No. 7 719 002 431 (125mm dia)
Accessories
Flue diameter 100mm 125mm
Flue terminal assembly diameter 135mm 135mm
Maximum flue length
(inc. terminal)
30CDi Conventional 9,400mm 18,500mm
40CDi Conventional 4,900mm 16,000mm
30CDi System 9,400mm 18,500mm
Flue terminal assembly length 1,140mm 1,365mm
Option 1
Vertical balanced flue system maximum height
Straight flue length
300mm
500mm
Pitched
roof
Flat roof
L = 100mm dia 1,140mm
L = 125mm dia 1,365mm
Maximum total straight flue length
(inc. terminal) 100mm dia 125mm dia
30CDi Conventional 9,400mm 18,500mm
40CDi Conventional 4,900mm 16,000mm
30CDi System 9,400mm 18,500mm
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 9 7 719 002 349
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 18 7 719 001 892
40CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 5 7 719 002 349
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 16 7 719 001 892
30CDi System
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 9 7 719 002 349
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 18 7 719 001 892
Minimum height
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
125mm Vertical Flue Kit 1 7 719 002 431
40CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
125mm Vertical Flue Kit 1 7 719 002 431
30CDi System
100mm Vertical Flue Kit 1 7 719 002 430
125mm Vertical Flue Kit 1 7 719 002 431
Option 2
Vertical balanced flue system with two 45º bends
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 8 7 719 002 349
100mm 45º Bend 2 7 719 002 347
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 17 7 719 001 892
125mm 45º Bend 2 7 719 001 899
40CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 3 7 719 002 349
100mm 45º Bend 2 7 719 002 347
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 14 7 719 001 892
125mm 45º Bend 2 7 719 001 899
30CDi System
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 8 7 719 002 349
100mm 45º Bend 2 7 719 002 347
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 17 7 719 001 892
125mm 45º Bend 2 7 719 001 899
Maximum total straight flue length
(inc. terminal) 100mm dia 125mm dia
30CDi Conventional 7,400mm 16,500mm
40CDi Conventional 2,900mm 14,000mm
30CDi System 7,400mm 16,500mm
Worcester Part No.
100mm dia 125mm dia
Extension Flue Kit (1,000mm) 7 716 191 083 7 719 001 892
90º Bend 7 716 191 084 7 719 001 891
45º Bend 7 716 191 085 7 719 001 899
Note: The roof flashing is not supplied by Worcester.
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 22