Technical data
2120
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 7,900mm 18,500mm
40CDi Conventional 2,600mm 12,500mm
30CDi System 7,900mm 18,500mm
Option 4
Extension flue horizontal and upwards
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 8 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 19 7 719 001 892
125mm 90º Bend 1 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
40CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 3 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 13 7 719 001 892
125mm 90º Bend 1 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 8 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 19 7 719 001 892
125mm 90º Bend 1 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
Option 5
Extension flue upwards and horizontal using a second
90º bend
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 6 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 18 7 719 001 892
125mm 90º Bend 2 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
40CDi Conventional
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 12 7 719 001 892
125mm 90º Bend 2 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 6 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 18 7 719 001 892
125mm 90º Bend 2 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 5,900mm 16,500mm
40CDi Conventional N/A 10,500mm
30CDi System 5,900mm 16,500mm
Option 6
Extension flue upwards and horizontal using a third
90º bend
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 4 7 716 191 083
60/100mm 90º Bend 3 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 17 7 719 001 892
125mm 90º Bend 3 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
40CDi Conventional
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 11 7 719 001 892
125mm 90º Bend 3 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 4 7 716 191 083
60/100mm 90º Bend 3 7 716 191 084
60/100mm Vertical Flue Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 17 7 719 001 892
125mm 90º Bend 3 7 719 001 891
125mm Vertical Flue Adaptor 1 7 719 002 433
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 3,900mm 14,500mm
40CDi Conventional N/A 8,500mm
30CDi System 3,900mm 14,500mm
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 20