Technical data
1918
Greenstar CDi regular & system
boiler series horizontal fluing options
Option 1
Standard horizontal flue assembly
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
125mm Standard Flue Kit 1 7 719 002 350
40CDi Conventional
60/100mm
Standard Telescopic
7 716 191 082
Flue Kit
1
125mm Standard Flue Kit 1 7 719 002 350
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
125mm Standard Flue Kit 1 7 719 002 350
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 570mm 1,070mm
40CDi Conventional 570mm 1,070mm
30CDi System 570mm 1,070mm
Option 2
Extension flue horizontal
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 8 7 716 191 083
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 18 7 719 001 892
40CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 3 7 716 191 083
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 12 7 719 001 892
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 8 7 716 191 083
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 18 7 719 001 892
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 7,900mm 18,500mm
40CDi Conventional 2,600mm 12,500mm
30CDi System 7,900mm 18,500mm
Option 3
Extension flue horizontal using a second 90º bend
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 6 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 17 7 719 001 892
125mm 90º Bend 1 7 719 001 891
40CDi Conventional
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 11 7 719 001 892
125mm 90º Bend 1 7 719 001 891
30CDi System
60/100mm
Standard Telescopic
1 7 716 191 082
Flue Kit
60/100mm 1,000mm Extension Kit up to 6 7 716 191 083
60/100mm 90º Bend 1 7 716 191 084
125mm Standard Flue Kit 1 7 719 002 350
125mm Flue Extension up to 17 7 719 001 892
125mm 90º Bend 1 7 719 001 891
Maximum total straight flue length
100mm dia 125mm dia
30CDi Conventional 5,900mm 16,500mm
40CDi Conventional N/A 10,500mm
30CDi System 5,900mm 16,500mm
The Greenstar CDi series has the choice of 2 differently
sized horizontal RSF flue systems, a 100mm diameter
telescopic flue kit and a 125mm diameter kit. Both systems
have different maximum lengths. Options 1 to 6 detail
the permissible lengths.
Horizontal RS flue
100mm dia standard telescopic flue kit
Comprises:
1 x flue turret elbow
570mm (100mm dia) of flue duct
Part No. 7 716 191 082
125mm dia standard flue kit
1 x flue turret elbow
1,030mm (125mm dia) of flue duct including terminal
(as measured from centre of flue outlet)
Part No. 7 719 002 350
*Can be cut to 130mm. Please refer to instructions.
Accessories
The following criteria should be noted when planning the
installation.
•
The concentric flue system must be inclined at 3º
(50mm per metre) from the appliance, to allow
condensate to drain back into the boiler.
•
Because the appliance operates at high efficiency a
white plume of condensation will be emitted from the
terminal. Care must be taken when selecting the flue
terminal position.
Worcester Part No.
100mm dia 125mm dia
Extension Flue Kit (1,000mm) 7 716 191 083 7 719 001 892
90º Bend 7 716 191 084 7 719 001 891
45º Bend 7 716 191 085 7 719 001 899
Vertical Flue Adaptor Kit 7 719 002 432 7 719 002 433
Support Bracket Kit 7 716 191 092 –
Flue diameter 100mm 125mm
Minimum flue length 350mm* 250mm
Maximum flue length
30CDi Conventional 7,900mm 18,500mm
40CDi Conventional 2,600mm 12,500mm
30CDi System 7,900mm 18,500mm
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 18