Technical data

1514
Option 5
EXTENSION FLUE UPWARDS AND HORIZONTAL USING
A SECOND 90˚ BEND
Flue Components Required
30CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 8 7 719 002 349
100mm 90º Elbow 2 7 719 002 348
100mm Vertical Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 18 7 719 001 892
125mm 90º Elbow 2 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
40CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 12 7 719 001 892
125mm 90º Elbow 2 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
Option 6
EXTENSION FLUE UPWARDS AND HORIZONTAL USING
A THIRD 90˚ BEND
40CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 11 7 719 001 892
125mm 90˚ Elbow 3 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
x 3
Flue Components Required
30CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 7 7 719 002 349
100mm 90º Elbow 3 7 719 002 348
100mm Vertical Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 17 7 719 001 892
125mm 90º Elbow 3 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
30CDi System
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 7 7 719 002 349
100mm 90º Elbow 3 7 719 002 348
100mm Vertical Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 17 7 719 001 892
125mm 90º Elbow 3 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
Option 4
EXTENSION FLUE HORIZONTAL USING A
SECOND 90˚ BEND
Flue Components Required
30CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 7 7 719 002 349
100mm 90˚ Elbow 1 7 719 002 348
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 17 7 719 001 892
125mm 90˚ Elbow 1 7 719 001 891
40CDi Conventional
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit 1 7 719 002 349
100mm 90˚ Elbow 1 7 719 002 348
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 11 7 719 001 892
125mm 90˚ Elbow 1 7 719 001 891
30CDi System
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 7 7 719 002 349
100mm 90˚ Elbow 1 7 719 002 348
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 17 7 719 001 892
125mm 90˚ Elbow 1 7 719 001 891
Maximum total straight flue length
100mm 125mm
30CDi Conventional 5,900mm 16,500mm
40CDi Conventional 600mm 10,500mm
30CDi System 5,900mm 16,500mm
Maximum total straight flue length
100mm 125mm
30CDi Conventional 5,900mm 16,500mm
40CDi Conventional N/A 10,500mm
30CDi System 5,900mm 16,500mm
30CDi System
Flue Diameter Description Quantity
Worcester Part No.
100mm Standard Flue Kit 1 7 719 002 497
100mm Extension Flue Kit up to 8 7 719 002 349
100mm 90º Elbow 2 7 719 002 348
100mm Vertical Adaptor 1 7 719 002 432
125mm Standard Flue Kit 1 7 719 002 350
125mm Extension Flue Kit up to 18 7 719 001 892
125mm 90º Elbow 2 7 719 001 891
125mm Vertical Adaptor 1 7 719 002 433
Maximum total straight flue length
100mm 125mm
30CDi Conventional 3,900mm 14,500mm
40CDi Conventional N/A 8,500mm
30CDi System 3,900mm 14,500mm
x 2
BBT181 Gstr CDi Conv T&S IssB 4/5/06 11:21 Page 14