User's Manual

http://www.woosim.com
14
2
2
.
.
5
5
.
.
S
S
e
e
t
t
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
m
m
o
o
d
d
e
e
1. Press the MODE Button until the Error Lamp twinkles 5 times.
2. Change the mode and option using the MODE Button according to the MODE
(Table1).
z MODE button : use for changing OPTION status. (Error Lamp)
z FEED button : use for changing MODE status. (Power Lamp)
Ex) The defaults of the printer are : RS-232C/ 9600 bps/ 8 data bit / No parity
/ Density Low
If a user wants to modify the defaults with Protocol IrDA / 38400 bps / 7 data
bit/ even parity/ density high
X Press MODE Button until Error Lamp twinkles 5 times and release the
button.
o
You will see the Power Lamp twinkles one time and the Error Lamp
twinkles 1 time.
o
Press the MODE Button one time and the Error Lamp twinkles twice.
(The interface mode has set to Protocol IrDA mode)
X Press FEED button one time, Power Lamp twinkles twice and Error Lamp
twinkles 4 times
o
Press MODE Button one time, Error Lamp twinkles 5 times and press
the MODE Button one more time, the Error Lamp twinkles 6 times
(The baud rate has set to 38,400 bps)