Treadmill Ergometer PPS Medical Series PPS 43 Plus PPS 55 Plus PPS 70 Plus PPS 43 Med PPS 55 Med PPS 70 Med PPS 43 Med-i PPS 55 Med-i PPS 70 Med-i PPS 43 Ortho PPS 55 Ortho PPS 70 Ortho Translation of the original German Operating Manual Edition: 05/2013-v1.
European Representative: Manufacturer: WOODWAY GmbH Steinackerstr. 20 79576 Weil am Rhein Germany WOODWAY USA, Inc. W229 N591 Foster Ct. Waukesha, WI 53186 USA Tel.: Fax.: E-Mail: Web: Tel.: Fax.: E-Mail: Web: +49 (0) 7621 - 940 999 - 0 +49 (0) 7621 - 940 999 - 40 info@woodway.de www.woodway.de Sales: Tel. +49 (0) 7621 - 940 999 - 10 E-Mail: vertrieb@woodway.de Customer Service: Tel. +49 (0) 7621 - 940 999 - 14 E-Mail: service@woodway.de +1 262 - 548 - 6235 +1 262 - 522 - 6235 info@woodway.com www.
Table of Contents 1 Table of Contents 1 Table of Contents .....................................................................................3 2 Introduction .............................................................................................5 2.1 2.2 2.3 2.4 2.5 2.6 3 Safety......................................................................................................9 3.1 3.2 3.3 3.4 3.5 3.6 3.7 4 Overview of Models ...............................................................
Table of Contents 8 Operation .............................................................................................. 39 8.1 8.2 8.3 8.4 8.5 8.6 8.7 Area of Application for Endurance Training................................... 39 Application Possibilities for Children ............................................. 40 Before Each Use ........................................................................ 40 Switching Device On/Off .............................................................
Introduction 2 Introduction 2.1 Operating Instructions Information This manual provides information on the safe operation of the WOODWAY slat-belt treadmill. One condition for safe operation is compliance with all safety and operating instructions. CAUTION Improper operation can cause accidents! Not using the slat-belt treadmill as intended according to the manufacturer's instructions can cause accidents and equipment damage.
Introduction 2.3 Copyright The release of the operating instructions to third parties without the written permission of WOODWAY GmbH is prohibited. NOTE All contents, text, drawings, images or other illustrations are copyright protected and are subject to intellectual property rights. Any misuse is punishable by law! Duplication in any manner and form - including excerpts - as well as use and/or communication of the content are not permitted without written permission from WOODWAY GmbH. 2.
Introduction 2.5 Customer Service For service questions, please contact as follows: WOODWAY GmbH Steinackerstr. 20 79576 Weil am Rhein GERMANY Contact: Tel. +49 (0) 7621 - 940 999 - 14 Fax. +49 (0) 7621 - 940 999 - 40 Email: service@woodway.
Introduction 2.6 Fig. 1 8 EC Declaration of Conformity CE Declaration of Conformity 05/2013-v1.
Safety 3 Safety 3.1 General PPS series treadmills have been reliably designed, manufactured and tested according to the latest state of technology and are in a safe and technically perfect condition. Nevertheless, the device can cause risk to persons and property if it is operated improperly. For this reason the operating instructions should be read completely and safety instructions must be observed. Warnings attached directly to the device must be observed and kept in a legible condition.
Safety 3.3 Markings on Device Safety relevant information is identified on the device using the following symbols: Protective Ground Wire Connection PPS series devices are electrical devices with protection class I. Danger Due to Electric Voltage This symbol warns the user of dangerous voltage inside the device. Danger of Being Crushed This symbol warns the user of potentially being crushed. CAUTION! - To reduce the risk of fire, replace only with same type and rating of fuse.
Safety 3.4 Personnel Qualifications and Responsibilities WARNING Danger Due to Improper Use! Improper handling of the device can lead to serious personal injury and property damage. ► The device may only be operated by persons who have received instructions from qualified service personnel. ► WOODWAY GmbH recommends the use of a training record (see appendix) for proof of instructions.
Safety In all fields of use the treatment of patients with a variety of physical and/or mental limitations is carried out (for example, gait impairments, limited reflexes, etc.). Special User Groups! Special attention must apply to these user groups. Compared to treadmill exercise with healthy people the risk of injury is considerably higher with these users. Strict adherence to and compliance with all safety instructions and operating information is the highest priority.
Safety In the following cases treadmill training may only be carried out after consultation with a doctor: Pregnancy acute thrombosis fresh wounds (e.g.
Safety 3.7 Electromagnetic Compatibility (EMC) It is expressly noted that ELECTRICAL MEDICAL EQUIPMENT is subject to special precautions regarding electromagnetic compatibility (EMC). They must be installed and operated accordingly. The PPS series treadmills meet the requirements of EN 60601-1-2:2001 (Group 1, CISPR 11 Class A), EN 61000-3-2 and EN 61000-3-3.
Technical Data 4 Technical Data 4.1 Name Plate The nameplate contains the device's main technical details. Keep handy for questions! For service questions, the technical information on the nameplate must be kept handy. Gerätes. Bei Rückfragen bereithalten! Bei servicetechnischen Rückfragen sind die Angaben auf dem Typenschild bereitzuhalten. 10 9 8 7 1 6 5 4 Fig. 2 3 2 Nameplate, sample 1. 2. 3. 4.
Technical Data 4.
Transportation and Storage 5 Transportation and Storage 5.1 Safety Notices for Transportation Check the treadmill for damage upon arrival. Also check and compare supplied accessories with the corresponding delivery note. The manufacturer is not liable for damages and missing parts if this information was not recorded in writing on the delivery note upon delivery of the unit. Damage or defects must be reported to the carrier and to the responsible WOODWAY dealer immediately.
Transportation and Storage 5.4 Transportation with Carrying Poles Four carrying poles (square steel pipes) are included as treadmill accessories. The carrying poles can be inserted into the front and back openings provided in the treadmill frame (Fig. 3 and Fig. 4). 1 Fig. 3 1. 2. 2 Carrying poles Use of carrying poles, PPS Plus model Use of carrying poles, PPS Med / PPS Ortho The treadmill may only are lifted at the indicated points. Fig.
Transportation and Storage 5.5 Removing / Mounting Side Handrails In most cases the WOODWAY is delivered completely assembled. In some cases the conditions at the intended location do not allow for assembly free delivery (doors, stairs, elevators, etc.) and the treadmill needs to be partially disassembled. DANGER Danger of Death by Electric Shock! Fatal electrical shock may occur if the unit is not disconnected from the power supply before assembly or disassembly.
Transportation and Storage Fig. 6 Disconnect cables: Remove electronics shielding panel Disconnect cables from display cable, emergency stop cable and the earth. First remove the cable ties that secure the wiring harness to the frame, Fig. 7. Fig. 7 Fixing of the wiring harness to the frame Ensure that the wires are not damaged! Then loosen the nut of the grounded star point, and then remove the two 25-pin D-SUB plugs, each fixed with two small Phillips screws, Fig. 8. 20 05/2013-v1.
Transportation and Storage Fig. 8 Treadmill controls (WLS) Now carefully pull the harness through the hole below the toroidal transformer, Fig. 9. Fig. 9 Removing the railing mount: Wiring harness layout Remove the railing mount and the railing. PPS Med or PPS Ortho: Loosen the upper fixing screw (M18) in the front and rear with a 5 mm Allen wrench, Fig. 10. Remove the (M18) fixing screw at the bottom with a 13 mm box wrench.
Transportation and Storage Fig. 10 Fixing bolts in railing mount PPS Ortho / PPS Med PPS Plus: Loosen the base frame mount using a 17 mm box wrench (one bolt per rail). The inner nut is secured by an additional counter nut. Pull the bar railings vertically out of the guide, Fig. 11. Fig. 11 Fixing bolts in railing mount PPS Plus 22 05/2013-v1.
Transportation and Storage Mounting the railing 1. 2. Mounting of the railing is carried in the opposite order. The following points must be checked during mounting: o o o o o 3. 4. Transportation notes: Are all cables in good condition? Are all bolts tight? No other plugs have been accidentally pulled out. Are all plugs properly inserted and screwed tight? Are the wires fixed to the treadmill frame with wire ties? Mount the side panels.
Product Description 6 Product Description 6.1 Overview of Models WOODWAY slat-belt treadmills are available in the following walking surface widths: 43 cm 55 cm 70 cm Due to the fact that several options are available the devices can be individually adapted.
Product Description 6.2 Equipment and Options WOODWAY slat-belt treadmills are available in the following walking surface widths: 43 cm 55 cm 70 cm Due to the fact that several options are available the devices can be individually adapted. Options: PPS 43/55/70 Med *) PPS 43/55/70 Ortho □ Speed 0-20 km/h Speed 0-24 km/h □ □ □ Incline 0-20% □ Incline 0-25% PPS 43/55/70 Plus □ □ Display data monitor x x Display WUS □ □ Display as ext. version □ □ □ x x Both sides.
Product Description 6.3 Main Components The main components are shown using the PPS Plus model: 1 8 2 7 6 3 4 5 Fig. 12 Device components, PPS Plus model 1. 2. 3. 4. 5. 6. 7. 8. 6.
Product Description Support system The support system consists of two supporting rails (secondary carrier), which are equipped with high-performance bearings. Six V-belt guides on each carrier ensure lateral stability. The system which consists of a total of 112 ball bearings supports the running surface and distributes the load evenly over the entire treadmill. The running surface belt (slats and steel wire reinforced toothed V-belt) is guided by a form-fitted drive pulley on the front and back.
Product Description 6.5 WOODWAY User-System Control and Display Elements The WOODWAY user system (WUS) is equipped with an LCD touch panel, which provides convenient operation of all treadmill and program functions. Creating your own training programs is also possible. The 5'' Screen (diagonal 125mm) provides a clear display of current training information. Fig. 14 WOODWAY User-System (WUS) WOODWAY Data monitor The WOODWAY data monitor (DaMo) display offers an alternative with reduced functionality.
Product Description WOODWAY User system, external The external WOODWAY user system (WUS), with emergency stop switch, is an optional WUS display as a desktop unit for the supervisor (therapists, sports physicians, or other supervisor). The external WOODWAY user system is also available as a supplement to the PPS Ortho. Fig. 16 WOODWAY User-System (WUS) external with emergency stop switch Keypad Keypad for PPS Ortho, or with spiral wire for PPS or PPS Med Plus.
Product Description 6.6 Safety Equipment The medical PPC series treadmills are equipped with different safety equipment depending on model and design. When needed, they serve to prevent dangerous situations and to reduce the risk of injury to a minimum.
Product Description On treadmills with a reverse direction function, the emergency stop button has a magnetic mount and can be freely positioned on the railing. Before starting a workout ensure that the emergency stop button can always be reached by the runner or the treadmill operator. Device users must always be positioned so that they can reach the emergency stop switch in any situation. Releasing: After pressing the emergency stop button it initially remains locked.
Product Description 1 3 2 Fig. 19 Emergency stop magnetic switch on the display 1. 2. 3. Clothing clip Pull cord, adjustable length Magnet Fig. 20 Emergency stop magnetic switch on emergency stop button on railing Depending on the model, the magnetic is either fixed in the position indicated on the display (red box with yellow ring, see Fig. 19), or on the emergency stop button on the railing (see Fig. 20).
Product Description Chest harness or waist strap Fall protection with emergency stop Provided the device is equipped with fall protection with emergency stop and the runner is secured by chest harness or waist strap, the clip must not be connected to the runner. The magnet must still be attached to the indicated point so that the treadmill is operational. The optional fall protection system for the treadmill serves to prevent accidents.
Commissioning 7 Commissioning 7.1 General Commissioning is the initial intended use of the device, see sec. 3.5 Page 11. Ensure that the conditions applicable to basic safety and health requirements are met. Read these operating instructions completely before commissioning. Before commissioning the device, operating and functional safety is to be tested. This includes correct installation, electrical connection, and operator training.
Commissioning The following further instructions for installation are to be observed: When installed on upper floors, the device must be placed as far as possible in a corner of the room so that sufficient stability is guaranteed, even at max. speed. The structure of the building must be checked in advance. The treadmill should not be installed close to a radiator or other heat source. This could cause technical defects.
Commissioning Adjust leveling feet: After positioning the device at the installation site, adjust the horizontal height using a level. The height of the four leveling feet can be adjusted. Fig. 22 Adjusting leveling feet Loosen the counter nut with a 19 mm open-end wrench Turn the foot up or down until the desired height has been reached Retighten the counter nut When making these adjustments it is important to ensure that the frame of the treadmill does not twist.
Commissioning 7.3 Electrical Connection DANGER Danger of Death by Electric Shock! Improper handling of electrical equipment by unqualified persons can cause fatal electrical shock. ► If necessary, allow only qualified personnel to perform electrical installation. ► The power cord must not come into contact with hot surfaces or sharp edges. ► Electrical parts such as motor, power cord and power switch must not come in contact with water.
Commissioning Ungrounded outlets may NOT be used! The use of power strips is not permitted! WARNING Danger of Injury by Tripping Over Wires! Improperly installed wires represent a tripping hazard and danger of injury. ► Safe laying of power cords, interface cable, etc. outside of walking areas. ► The use of wiring channels. 7.4 Completion of Commissioning Prior to starting operation, commissioning is to be completed with a trial run.
Operation 8 Operation WARNING Danger Through Uncontrolled Running Surface Movement! By stepping on the rear most part of the running surface where it is rounded, the force of gravity can set the running surface in motion. There is a danger of falling! ► The user must not step on the rounded part of the running surface when mounting and dismounting! 8.1 Area of Application for Endurance Training Medical PPS series slat-belt treadmills allow speeds of up to 24 km/h.
Operation 8.2 Application Possibilities for Children Due to their design and operation, PPS series slat-belt treadmills are only for limited use by children. WARNING Special Hazards Associated with Treadmill use by Children! There is an increased risk of accidents through the use of treadmills by children. The following special instructions apply for children: ► Children may only be near the treadmill under supervision. ► The treadmill must be equipped with the "child railing".
Operation 8.4 Switching Device On/Off NOTE Ensure that NO emergency stop button or emergency stop mushroom is engaged. The emergency stop magnet with pull cord must be attached to the field marked for this purpose.
Operation 5. Switch the device off via the main switch on the power supply console when it will not be used for a long time. 1 2 Fig. 24 On switch PPS Ortho 1. 2. Emergency stop switch with magnet and pull line in place On switch ATTENTION Do not move the running surface belt during th4e initialization phase (approx. 3-4 seconds)! The movement can be interpreted as a device malfunction by the control electronics and switch off the device.
Operation 8.5 Using the Keypad The keypad can be attached to a suitable point on the handrail so that the controls are easily accessible to the runner. The magnetic mount makes it possible to remove the keypad from the railing. In this way the runner's supervisor can use the keypad as a remote control. Fig. 25 Keypad with magnetic mount Switch device on as0 Page 41 as described in sec.
Operation 8.6 Operating the Data Monitor (DaMo) The data monitor has 4 multi-digit displays to indicate the current training parameters as well as several LEDs to indicate the control mode.
Operation Distance and calorie consumption: In the display (Pos. 9) the distance in kilometers and calorie consumption of the runner since the last time the treadmill was switched on are alternately shown at intervals of 10 seconds. The upper value shows the distance and the lower value the calorie consumption. The distance and calorie values are maintained after the treadmill is stopped. They are deleted after restarting the treadmill using the keypad on the railing or the remote control.
Operation 8.7 Operation with Woodway User System (WUS) The WOODWAY user system (WUS) is used to display the current parameters, the control modes and to operate the treadmill. In addition, in the WUS housing contains the stand-by button (on the right side of the housing), the contact surface for the emergency stop magnet with integrated pull cord and clip or an emergency stop button (external display), which the operator can trigger. 1 6 2 3 5 4 Fig. 27 WUS control panel 1. 2. 3. 4. 5. 6.
Operation By pressing the green button on the right side of the display (Pos. 4), the treadmill is turned on. After the initialization the „START“ button appears in the display. The device is now ready for operation. By pressing the „START“ button the main menu is opened. Fig. 29 WUS main menu 8.7.1 Manual Operation For manual input of speed and incline press the MANUAL button at the top left. The following display appears: 1 2 3 Fig. 30 WUS manual 1. 2. 3. Speed: (Pos.
Operation In manual mode the following values appear in the display. 8.7.2 Speed, in either km/h or miles/h or m/s Current incline in % Distance, either in kilometers (km) or miles Training duration in hh:mm:ss Heart rate in bpm (beats per minute), indicated with a heart symbol Power in watts or energy in kcal Current treadmill speed, either in km/h or miles/h or m/s or an indication of the power in watts vs.
Operation A vertical line moves from left to right and shows you your position in the program. In addition, you see the following information: Current speed of the treadmill, either in km/h or miles/h or m/s, select the unit Current incline in % Distance, in either km/h or miles/h or m/s Training duration in hh.mm.ss Heart rate in bpm (beats per minute) If the Polar chest strap is used, the pulse rate is displayed in beats per minute (bpm).
Operation EDIT PROGRAM: The selected program can be edited here: Fig. 34 WUS edit program - and + BUTTON: SPEED etc.: Changes the respective program steps The parameter to be changed is selected. Then the new values are entered as shown below: Fig. 35 WUS change program parameters Confirm: Cancel: Accept the entered values. Return to previous menu. After confirmation the edit program menu appears, Fig. 34. Here program editing is continued or ended: Save: 50 Saves the edited program.
Operation 8.7.4 Create Program The process for creating a new program corresponds to the process for editing an existing program. Select the EDIT PROGRAM button in the main menu (Fig. 29). Then select the CREATE PROGRAM button. Now proceed exactly as when editing a program by changing the individual parameters. The program name can be freely defined by pressing the NAME button. Enter the program name by entering it into the following screen: Fig.
Operation After selecting a program, the following screen appears: Fig. 37 WUS pulse control Here, you must first enter the age using the "Age" button and the physical condition using the "physical condition" button. Enter the information in the following screen: Fig. 38 WUS enter program parameters FAT BURNING: CARDIOVASCULAR TRAINING: EDIT TARGET PULSE: LIMIT CONTROL: END: Cancel: 52 Suggests a pulse limit for a fat burning workout based on the entered age and physical condition.
Operation 8.7.6 Edit parameters: Edit/Show Parameters To change parameters select the "EDIT PARAMETERS" option in the start menu. Fields with adjustable parameters will be displayed: Fig. 39 WUS edit parameters The desired values can be set by pressing the respective buttons. The set values appear on the screen, for example, Language: German, speed in km/h. By pressing the END button the set values are accepted and the main menu is displayed again.
Operation 8.8 Adjustment of Bar Rails PPS Plus type treadmills are equipped with bar railing. The PPS and PPS Med Ortho models are optionally available with a bar railing. Depending on the design, the flexible handrail allows it to be adapted to the height and width of the individual user.
Operation 8.9 Reversing the Direction Depending on the model, the treadmill has a reversing direction function, or can be retrofitted if necessary. Information available at WOODWAY dealer WOODWAY Customer Service. If the treadmill is equipped with the reverse mode, it can be activated in two different ways.
Operation 8.10 Body Weight Support Systems Depending on the illness may be necessary to use a body weight support system for the treadmill therapy in motor rehabilitation. NOTE A separate manual is supplied with the body weight support system! For information on the use of body weight support systems please contact your WOODWAY local dealer or service center. ATTENTION When using the body weight support system, PPS series treadmills must be equipped with an additional brake (retrofitting possible).
Options and Accessories 9 Options and Accessories 9.1 Order Numbers The following accessories and options can be obtained from a WOODWAY dealer or WOODWAY service center. Will the accessories fit? Depending on year and equipment, it should be checked in advance whether the particular unit is suitable for the selected accessories/options. For this contact the WOODWAY dealer or WOODWAY service center before ordering.
Options and Accessories 9.2 Video Railing for PPS Ortho The cross member on the front part of the PPS Ortho handrail can be removed if required using two quick releases. The unblocked view or video analysis of patients is possible from the front and from behind. WARNING Danger of Injury by Falling! In the event of a fall in reverse mode when the crossbar is mounted serious injury can occur.
Options and Accessories 1 2 Fig. 45 PPS Ortho video railing 1. 2. 9.3 Incorrect lever position of the quick disconnect, danger of injury! Pull out the lever, turn it 90° and release it again Correct lever position for the quick disconnect, the lever rests on the crossbar! Mounting Aid To ensure safe mounting on the treadmill, patients with physical limitations may have to depend on expert personnel for support. Mounting the device may be further facilitated using a commercial climbing aid. Fig.
Options and Accessories Following further safety measures must be considered: 1. 2. 3. 4. 9.4 Before using the treadmill, the mounting aid must be removed from behind the treadmill, so that the requirements on the safety area (clear "fall area") of at least 2.00 x 1.00 m (length x width) behind the treadmill are met. To prevent damage to the treadmill and the mounting aid, this must never come in contact with the running surface.
Options and Accessories 9.5 USB to Serial Converter A "USB to Serial" adapter allows the connection of devices with serial interface (RS232), e.g. modem, mouse etc. to a free USB port on your PC or notebook. Depending on the manufacturer, in rare cases there can be communication problems between the PC / notebook and the treadmill. The industrial USB-to-serial adapter of the brand ATEN (Model UC-232A), which can be obtained from the WOODWAY customer service can be recommended as a proven model. Fig.
Options and Accessories 9.6 Interface Wire To control the treadmill via PC or laptop the serial interface of the treadmill must be connected with the computer via a so-called null-modem cable with two D-SUB connectors (9-pin, female). This interface wire must be shielded and must not exceed a length of 5 meters. The cable is commercially available or can be obtained from the WOODWAY customer service. Fig.
Maintenance and Cleaning 10 Maintenance and Cleaning WARNING Danger of Injury due to Lack of Qualifications! If maintenance or repairs are not carried out by professionally qualified personnel, this may cause material damage and serious injury. ► Maintenance and repair work may only be performed by qualified personnel! ► It is the sole responsibility of the representative to assign qualified personnel for maintenance and repair work.
Maintenance and Cleaning Cleaning agent 10.2 For cleaning and disinfection of parts that are touched (handrail, display, controls, etc.) a formaldehyde-free rapid disinfectant such as "Bacillol plus" or "Descosept" is recommended. For cleaning, never use sharp brushes or abrasive cleaning agents, paint and plastic surfaces can be damaged. Maintenance Intervals DANGER Danger of Death by Electric Shock! Maintenance and inspection work on the unit may cause serious or fatal electrical shock.
Maintenance and Cleaning Maintenance every 2-4 weeks A complete function test the treadmill must be carried out every 2-4 weeks depending on the duration and intensity of use. The function test includes the following: 1. Using the treadmill for a short time at speeds between 6 and 10 km/h. Do unusual noises occur? 2. Stand next to the treadmill and turn it up to maximum speed for a short time. Does the treadmill reach the specified maximum speed? Do unusual noises occur? 3.
Maintenance and Cleaning A repair must take place: Annual maintenance if liquid has gotten into the device, with damaged power cord (cable, plug) if the drive system toothed belt of the shows deficiencies in case of suspected bearing damage, if a defect on the device is suspected or has already been established, in case of bucking, sudden stopping or accelerating of the running surface, if buttons fail to function, in case of burning smell, smoke, or unusual noises, in case of malf
Maintenance and Cleaning 10.3 Technical Safety Checks (TSC) Medical PPS series treadmills are devices in protection class I and have an application part in type B (railing). The power cord is normally not removable. Permanent connection Checks and measurements Country-specific requirements PPS Series devices are usually not intended for permanent connection. The installation of a permanent connection must be performed by suitably trained personnel.
Maintenance and Cleaning Visual inspection Measurements i.a. EN 62353:2008 According to section 5.2 of the standard EN 62353, an inspection is carried out visually prior to the measurements. The following points must be checked on PPS series devices: 1. Treadmill operating manual. Is (i) the operating manual for the device immediately available for the user, and (ii) it is valid for the tested treadmill model? 2. Accessory operating manuals.
Maintenance and Cleaning A measurement of the insulation resistance in accordance with section 5.3.4 of the standard may NOT be performed. If the measured values are between 90% and 100% of the allowable limit, the previously measured values (reference values) for the evaluation of the electrical safety of the appliance shall be considered. Note that the measured values of the factory test may differ slightly from the measured values at each treadmill location due to different test conditions.
Maintenance and Cleaning Technical safety checks (after repeat tests or testing after maintenance and repair) may only be performed by, one who has the responsibility for the proper implementation of safety controls due to their training, knowledge and experience gained by practical activities, is not subject to instructions with reference to the inspection activities (i.e.
Maintenance and Cleaning The removal of the power plug from the outlet alone is not sufficient for the disabling of the treadmill, since third persons who have not been informed about the disabling can plug the treadmill back into the power supply and use it. The following measures must therefore be taken to disable a PPS series treadmill: 1. 2. 3. 4. 5. The unit must be turned off and the power plug must be unplugged from the wall socket (disconnection).
Maintenance and Cleaning 10.5 Device Fuses The fuses must comply with the published technical specifications, see sec. 4.3 Page 16. Bridging the fuses is prohibited (risk of electric shock, fire risk). When replacing a fuse, turn off the power using the main power switch and unplug the power cord from the outlet. Using a screwdriver, unscrew the fuse holder out of the power junction box. Change the fuse and screw the fuse holder into terminal box. Fig. 50 Device fuses 72 05/2013-v1.
Troubleshooting 11 Troubleshooting ATTENTION With the exception of the maintenance work described in this chapter, the treadmill can only be checked and repaired by qualified personnel. If necessary the WOODWAY dealer or service center is to be contacted! For inquiries have the following information handy: 11.
Troubleshooting 11.2 No Display If the display is not lit when you turn the treadmill, check the following points: 11.3 Is the emergency stop mushroom released (or emergency stop button on the external display)? Is the treadmill connected to the power source? If the main switch on the power connector box switched on? Fuse (s) blown? (Replace fuse) Can the fan is to cool the servo controller (on the right) be heard? Does the socket to which the treadmill is connected supply power (e.g.
Troubleshooting 11.6 Serial RS-232 Interface Possible causes of a serial interface malfunction are: 11.7 Defective wire connection in adequate pin allocation for the components Incorrectly set component protocols (Treadmill, PC, EKG, Spiroergometry) Improperly configured connection settings between the components (COM Port) Electrostatic Discharge By running on the device the runner can become electrostatically charged.
Disposal 12 Disposal The disposal of the equipment must be in accordance with the respective national regulations. Electrical and electronic devices must be disposed of separately from normal household waste. An appropriate waste disposal company should be contacted. Properly dispose of the device at the end of its service life (e.g. the local collection point for waste separation): The device packaging is disposed of through resource recycling.
Instruction Record 13 Instruction Record Once the introduction, installation and functional check of the slat belt treadmill has been completed, the competent WOODWAY employee or the authorized WOODWAY dealer carries out the instruction for the device. All persons who will be working with the unit in the future (user) must receive the instructions. After successful commissioning and instructions the instruction record is signed by the instructor all persons trained and a copy must be sent to WOODWAY GmbH.
Instruction Record Step 13 14 Description Conducted Notice to the RS232 port and CD with treadmill control software, as well as the accompanying user guide. Instructions on cleaning the treadmill with reference to the manual. Important notices: 15 When cleaning the unit always pull the power plug before the start.
Instruction Record Confirmation of commissioning and training record With the signing of the instruction record, the instructor and the customer confirm the carrying out of qualified instruction and commissioning.
Declaration of Conformity with Technical Regulations 14 Declaration of Conformity with Technical Regulations WOODWAY hereby confirms that the medical device "WOODWAY slat-belt medical PPS series treadmill" complies with the applicable generally accepted rules of technology and the requirements of occupational safety and is designed and manufactured so that users, patients and third parties are protected during its use against all kinds of hazards to life and health. 1. 2. 3. 4. 5. 6. 7. 8.
Table of Figures 15 05/2013-v1.0en Table of Figures Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig. Fig. Fig. Fig. 17 18 19 20 Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 CE Declaration of Conformity ...............................................
Table of Figures Fig. 49 Fig. 50 82 USB Interface wire RS-232 (2 × D-SUB 9-pin), configuration "minimum" null-modem wire.............................................................. 62 Device fuses ..................................................................................... 72 05/2013-v1.