Technical data
Maintenance and Cleaning
72 02/2014-v1.0en
9.2 Maintenance Intervals
DANGER
Danger of death by electric shock!
Maintenance and inspection work on the unit may cause serious or fatal elec-
trical shock.
► Pull the power plug prior to any maintenance and inspection work on the
equipment. The device must not be connected to the power!
► Ensure the device cannot be switched back on.
Weekly Maintenance
Clean handrails, display and side covers with a damp cloth.
Disinfect railings and controls.
Clean the running surface with a damp, lint-free cloth.
Visual check the power cord for damage.
Check the treadmill for mechanical damage.
Checking mounting of all control elements.
Clean the area under the treadmill (vacuum and mop).
CAUTION
Worn or damaged components must be replaced immediately. If the observed
deficiency can cause danger to the user or operator of the treadmill, it needs
to be taken out of service until repaired.
Semi-Annual Maintenance
Preventive maintenance consists of the following measures:
Vacuum dust from the inside of the treadmill (pull the treadmill plug and re-
move the side covers).
Check all nuts and bolts. Tighten loose nuts and bolts.
Clean the running surface.
Check the toothed belt and replace it when teeth are missing or badly worn.
Annual Maintenance
Significant measures for inspection of the treadmill:
Lubricate the roller bearings in the front and back.